Foco pulmonar facticio con 18F-FDG: posible error en la interpretación de la PET-CT

M.C. Redal Peña , F.J. Pena Pardo , J. Muñoz Iglesias , A. Crespo-Jara , J. Rebollo , A. Brugarolas Masllorens
{"title":"Foco pulmonar facticio con 18F-FDG: posible error en la interpretación de la PET-CT","authors":"M.C. Redal Peña ,&nbsp;F.J. Pena Pardo ,&nbsp;J. Muñoz Iglesias ,&nbsp;A. Crespo-Jara ,&nbsp;J. Rebollo ,&nbsp;A. Brugarolas Masllorens","doi":"10.1016/j.remn.2010.07.007","DOIUrl":null,"url":null,"abstract":"<div><p><sup>18</sup>F-FDG PET-CT has become an essential tool in oncology patient management. The normal distribution of the FDG and the possible artifacts (pitfalls), including those from CT-based attenuation correction, have already been described in several reviews.</p><p>However, only a few cases of FDG focal lung uptake have been reported recently.</p><p>We present two cases of oncology patients during a routine follow-up with this type of pitfall, without morphological correlation in the CT scan. We repeated the study in one of them, which made it possible to verify normalization of the hyperuptake, orienting us towards a possible pitfall.</p></div>","PeriodicalId":54464,"journal":{"name":"Revista Espanola De Medicina Nuclear","volume":"30 4","pages":"Pages 248-250"},"PeriodicalIF":0.0000,"publicationDate":"2011-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.remn.2010.07.007","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Espanola De Medicina Nuclear","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0212698210002223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

18F-FDG PET-CT has become an essential tool in oncology patient management. The normal distribution of the FDG and the possible artifacts (pitfalls), including those from CT-based attenuation correction, have already been described in several reviews.

However, only a few cases of FDG focal lung uptake have been reported recently.

We present two cases of oncology patients during a routine follow-up with this type of pitfall, without morphological correlation in the CT scan. We repeated the study in one of them, which made it possible to verify normalization of the hyperuptake, orienting us towards a possible pitfall.

18F-FDG假肺焦点:PET-CT解释可能存在错误
18F-FDG PET-CT已成为肿瘤患者管理的重要工具。FDG的正态分布和可能的伪影(陷阱),包括基于ct的衰减校正,已经在几篇综述中进行了描述。然而,最近仅报道了少数FDG局灶性肺摄取病例。我们提出两例肿瘤患者在常规随访与这种类型的陷阱,没有形态学相关的CT扫描。我们在其中一个病例中重复了这项研究,这使得我们有可能验证过度摄取的正常化,从而使我们指向一个可能的陷阱。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信