{"title":"Spectral findings for vowels [a] and [ã] at different velopharyngeal openings.","authors":"Aveliny Mantovan Lima-Gregio,&nbsp;Jeniffer de Cássia Rillo Dutka-Souza,&nbsp;Viviane Cristina de Castro Marino,&nbsp;Maria Inês Pegoraro-Krook,&nbsp;Plínio Almeida Barbosa","doi":"10.1590/s0104-56872010000400026","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The size control of velopharyngeal opening is an important variable for the acoustic profile characterization of hypernasal speech.</p><p><strong>Aim: </strong>To investigate frequency spectral aspects of F1, F2, F3, nasal formant (FN) and anti-formant, in Hertz, for vowels [a] and [ã] at different velopharyngeal openings produced in the bulb of a palatal prosthesis replica used by a patient with velopharyngeal insufficiency.</p><p><strong>Method: </strong>Speech recordings were obtained for four words (\"pato/mato\" and \"panto/manto\") produced within a carrier phrase in 5 conditions of velopharyngeal functioning: prosthesis with no openings (control condition: CC); prosthesis with bulb opening of 10 mm² (experimental condition with 10 mm² opening: EC10), prosthesis with a 20 mm² opening (EC20), prosthesis with a 30 mm² opening (EC30), and without the prosthesis (ECO). Five speech-language pathologists made a live rating of speech nasality during the reading of an oral passage. The recordings were used for spectral analysis.</p><p><strong>Results: </strong>F1 values were significantly higher for [a] when compared to [ã] in all conditions. F2 values for [a] in EC20 and EC30 were significantly lower than values in the other conditions, being closer to the values presented for [ã]. F3 values were not significantly different between the testing conditions. There was a relationship between FN and anti-formants, and the auditory perception of nasality for conditions EC10 and EC20.</p><p><strong>Conclusion: </strong>Significant changes were observed in the studied spectral values according to changes in the velopharyngeal opening size.</p>","PeriodicalId":74581,"journal":{"name":"Pro-fono : revista de atualizacao cientifica","volume":"22 4","pages":"515-20"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1590/s0104-56872010000400026","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pro-fono : revista de atualizacao cientifica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/s0104-56872010000400026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Background: The size control of velopharyngeal opening is an important variable for the acoustic profile characterization of hypernasal speech.

Aim: To investigate frequency spectral aspects of F1, F2, F3, nasal formant (FN) and anti-formant, in Hertz, for vowels [a] and [ã] at different velopharyngeal openings produced in the bulb of a palatal prosthesis replica used by a patient with velopharyngeal insufficiency.

Method: Speech recordings were obtained for four words ("pato/mato" and "panto/manto") produced within a carrier phrase in 5 conditions of velopharyngeal functioning: prosthesis with no openings (control condition: CC); prosthesis with bulb opening of 10 mm² (experimental condition with 10 mm² opening: EC10), prosthesis with a 20 mm² opening (EC20), prosthesis with a 30 mm² opening (EC30), and without the prosthesis (ECO). Five speech-language pathologists made a live rating of speech nasality during the reading of an oral passage. The recordings were used for spectral analysis.

Results: F1 values were significantly higher for [a] when compared to [ã] in all conditions. F2 values for [a] in EC20 and EC30 were significantly lower than values in the other conditions, being closer to the values presented for [ã]. F3 values were not significantly different between the testing conditions. There was a relationship between FN and anti-formants, and the auditory perception of nasality for conditions EC10 and EC20.

Conclusion: Significant changes were observed in the studied spectral values according to changes in the velopharyngeal opening size.

元音[a]和[ã]在不同腭咽开口处的频谱发现。
背景:腭咽开口的大小控制是高鼻音语音声学特征的一个重要变量。目的:研究腭咽功能不全患者使用的腭假体复制品球泡产生的不同腭咽开口处元音[a]和[ã]的F1、F2、F3、鼻峰(FN)和反峰(hz)的频谱特征。方法:在5种腭咽功能条件下,对载体短语中产生的“pato/mato”和“panto/manto”四个词进行录音:无开口假体(对照条件:CC);球茎开口为10 mm²的假体(实验条件为10 mm²开口:EC10)、开口为20 mm²的假体(EC20)、开口为30 mm²的假体(EC30)和不带假体(ECO)。五名语言病理学家在阅读一篇口语文章时对语音鼻音进行了现场评分。这些记录被用于光谱分析。结果:在所有条件下,[a]的F1值都明显高于[ã]。[a]在EC20和EC30中的F2值明显低于其他条件下的F2值,更接近于[ã]给出的值。F3值在不同测试条件下无显著差异。在EC10和EC20条件下,FN和反共振峰与鼻声听觉感知之间存在关系。结论:所研究的频谱值随咽口大小的变化而发生显著变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信