[Development of indicators to assess the stability of remnant blood samples stored in a biobank: experience at one institution].

Sae Hwan Kim, Young Eun Kang, Young Jun Hong, Yoon Hwan Chang, Seok-Il Hong, Ae-Chin Oh, Jin Kyung Lee
{"title":"[Development of indicators to assess the stability of remnant blood samples stored in a biobank: experience at one institution].","authors":"Sae Hwan Kim,&nbsp;Young Eun Kang,&nbsp;Young Jun Hong,&nbsp;Yoon Hwan Chang,&nbsp;Seok-Il Hong,&nbsp;Ae-Chin Oh,&nbsp;Jin Kyung Lee","doi":"10.3343/kjlm.2010.30.6.718","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>One of the major concerns with biobanking is the absence of standard operating procedures to eliminate pre-analytical variation arising from sample collection, preparation, and storage. Currently, there is a lack of tools to carry out quality control procedures for stored blood samples. The aim of this study is to assess the quality of stored blood samples in our biobank and to suggest appropriate indicators for their quality control.</p><p><strong>Methods: </strong>The stored blood samples that we tested have been registered into our biobank since 2003. These were transferred to our biobank after carrying out routine requested tests, because the samples would have otherwise been discarded. For the purpose of quality control, we analyzed the concentrations and the integrity of DNA and RNA extracted from the stored samples and tested the levels of several serum proteins; the results were compared with the corresponding pre-storage levels.</p><p><strong>Results: </strong>A total of 19 samples were stored from 2006 to 2009. Of the 22 samples stored between 2003 and 2005, 50% showed complete DNA integrity. However, sufficient RNA integrity was noted in only 1 sample stored as recently as 2009. High blood urea nitrogen levels were also noted in the stored sera, but the increase did not correlate to the duration of storage.</p><p><strong>Conclusions: </strong>The amount and integrity of nucleic acids extracted from stored blood samples are potential indicators that can be used for quality control. A guideline for the quality assessment of stored blood samples in a biobank is urgently needed.</p>","PeriodicalId":17890,"journal":{"name":"Korean Journal of Laboratory Medicine","volume":"30 6","pages":"718-25"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3343/kjlm.2010.30.6.718","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: One of the major concerns with biobanking is the absence of standard operating procedures to eliminate pre-analytical variation arising from sample collection, preparation, and storage. Currently, there is a lack of tools to carry out quality control procedures for stored blood samples. The aim of this study is to assess the quality of stored blood samples in our biobank and to suggest appropriate indicators for their quality control.

Methods: The stored blood samples that we tested have been registered into our biobank since 2003. These were transferred to our biobank after carrying out routine requested tests, because the samples would have otherwise been discarded. For the purpose of quality control, we analyzed the concentrations and the integrity of DNA and RNA extracted from the stored samples and tested the levels of several serum proteins; the results were compared with the corresponding pre-storage levels.

Results: A total of 19 samples were stored from 2006 to 2009. Of the 22 samples stored between 2003 and 2005, 50% showed complete DNA integrity. However, sufficient RNA integrity was noted in only 1 sample stored as recently as 2009. High blood urea nitrogen levels were also noted in the stored sera, but the increase did not correlate to the duration of storage.

Conclusions: The amount and integrity of nucleic acids extracted from stored blood samples are potential indicators that can be used for quality control. A guideline for the quality assessment of stored blood samples in a biobank is urgently needed.

[制定评估生物库中保存的残余血液样本稳定性的指标:某机构的经验]。
背景:生物库的主要问题之一是缺乏标准操作程序来消除样品收集、制备和储存引起的分析前变异。目前,缺乏对储存的血液样本实施质量控制程序的工具。本研究的目的是评估我们生物库中储存的血液样本的质量,并提出适当的质量控制指标。方法:自2003年起,我们检测的血液样本已注册到我们的生物库。在进行了常规要求的测试后,这些样本被转移到我们的生物库,否则这些样本将被丢弃。为了质量控制,我们分析了从储存样品中提取的DNA和RNA的浓度和完整性,并测试了几种血清蛋白的水平;结果与相应的贮藏前水平进行了比较。结果:2006 - 2009年共采集标本19份。在2003年至2005年间储存的22个样本中,有50%显示出完整的DNA完整性。然而,在最近的2009年,只有1个样本中发现了足够的RNA完整性。在储存的血清中也发现了高尿素氮水平,但升高与储存时间无关。结论:从保存的血液标本中提取核酸的数量和完整性可作为质量控制的潜在指标。目前迫切需要一份生物库中储存血液样本的质量评估指南。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Korean Journal of Laboratory Medicine
Korean Journal of Laboratory Medicine 医学-医学实验技术
自引率
0.00%
发文量
1
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信