On the Measurement of Electrical Impedance Spectroscopy (EIS) of the Human Head.

Giorgio Bonmassar, Sunao Iwaki, Gregory Goldmakher, Leonardo M Angelone, John W Belliveau, Michael H Lev
{"title":"On the Measurement of Electrical Impedance Spectroscopy (EIS) of the Human Head.","authors":"Giorgio Bonmassar,&nbsp;Sunao Iwaki,&nbsp;Gregory Goldmakher,&nbsp;Leonardo M Angelone,&nbsp;John W Belliveau,&nbsp;Michael H Lev","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We are introducing a system for Electrical Impedance Spectroscopy (EIS) measurements for future use in Neurological Intensive Care Unit (NICU) settings. The system consists mostly of commercially available components and the software was developed in Labview (National Instruments). The system is based on the principle that acute hemorrhagic stroke may produce detectable changes in the impedance spectrum measured on the subject's scalp due to parenchimal local increases of blood volume. EIS measurements were performed on four healthy control subjects to establish a baseline for a real time stroke detector. Measurements were performed using white noise currents in the 0-50 kHz frequency band using ten shielded electrodes placed on a subject's scalp, with electrical potentials measured with a large-dynamic range for increased EIS accuracy. EIS measurements yielded highly symmetrical impedance spectra, which was only obtainable using the proposed continuos spectral electrical impedance estimation.</p>","PeriodicalId":33683,"journal":{"name":"International Journal of Bioelectromagnetism","volume":"12 1","pages":"32-46"},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2997709/pdf/nihms205893.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Bioelectromagnetism","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We are introducing a system for Electrical Impedance Spectroscopy (EIS) measurements for future use in Neurological Intensive Care Unit (NICU) settings. The system consists mostly of commercially available components and the software was developed in Labview (National Instruments). The system is based on the principle that acute hemorrhagic stroke may produce detectable changes in the impedance spectrum measured on the subject's scalp due to parenchimal local increases of blood volume. EIS measurements were performed on four healthy control subjects to establish a baseline for a real time stroke detector. Measurements were performed using white noise currents in the 0-50 kHz frequency band using ten shielded electrodes placed on a subject's scalp, with electrical potentials measured with a large-dynamic range for increased EIS accuracy. EIS measurements yielded highly symmetrical impedance spectra, which was only obtainable using the proposed continuos spectral electrical impedance estimation.

Abstract Image

Abstract Image

Abstract Image

人体头部电阻抗谱(EIS)测量的研究。
我们正在介绍一种电阻抗谱(EIS)测量系统,用于未来神经重症监护病房(NICU)的设置。该系统主要由市售元件组成,软件在Labview (National Instruments)中开发。该系统的原理是,急性出血性中风可能会由于脑内局部血容量的增加而在受试者头皮上测量的阻抗谱中产生可检测的变化。对4名健康对照受试者进行EIS测量,以建立实时脑卒中检测器的基线。测量使用0-50 kHz频段的白噪声电流,使用放置在受试者头皮上的10个屏蔽电极,并在大动态范围内测量电位,以提高EIS精度。EIS测量产生了高度对称的阻抗谱,这只能使用所提出的连续谱电阻抗估计来获得。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信