New Continuous Miniature Crystal Element (cMiCE) Detector Geometries.

Robert S Miyaoka, Xiaoli Li, Cate Lockhart, Tom K Lewellen
{"title":"New Continuous Miniature Crystal Element (cMiCE) Detector Geometries.","authors":"Robert S Miyaoka, Xiaoli Li, Cate Lockhart, Tom K Lewellen","doi":"10.1109/NSSMIC.2009.5401844","DOIUrl":null,"url":null,"abstract":"<p><p>Continuous miniature crystal element (cMiCE) detectors are a potentially lower cost alternative to high resolution discrete crystal designs. We report on the intrinsic spatial resolution performance for two cMiCE PET detector designs with depth of interaction (DOI) positioning capability. The first detector utilizes a 50 mm by 50 mm by 8 mm LYSO crystal coupled to a 64 channel, multi-anode PMT. It provides 4 layers of DOI information. The crystal has beveled edges along two of its sides to improve the detector packing when placed in a ring geometry. The second detector utilizes a 50 mm by 50 mm by 15 mm, rectangular LYSO crystal coupled to a 64 channel, multi-anode PMT. It provides up to 15 layers of DOI information. The average intrinsic X, Y spatial resolution for the 8 mm thick, truncated crystal detector was 1.33 +/- 0.31 mm FWHM (45.6 mm by 46.6 mm useful imaging area). The average DOI resolution was 3.5 +/- 0.22 mm. The average intrinsic X, Y spatial resolution for the 15 mm thick crystal detector was 1.74 +/- 0.35 mm FWHM (44.6 mm by 44.6 mm useful imaging area). In addition, the average DOI spatial resolution for 56 test points spanning a 26.4 mm by 12.2 mm region of the crystal was 4.80 +/- 0.36 mm. We believe the 8 mm thick truncated crystal design is suitable for mouse imaging while the 15 mm thick crystal design is more suited for human organ specific imaging systems (e.g., breast and brain).</p>","PeriodicalId":73298,"journal":{"name":"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium","volume":"2009 ","pages":"3639-3642"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2898204/pdf/nihms-207150.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2009.5401844","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Continuous miniature crystal element (cMiCE) detectors are a potentially lower cost alternative to high resolution discrete crystal designs. We report on the intrinsic spatial resolution performance for two cMiCE PET detector designs with depth of interaction (DOI) positioning capability. The first detector utilizes a 50 mm by 50 mm by 8 mm LYSO crystal coupled to a 64 channel, multi-anode PMT. It provides 4 layers of DOI information. The crystal has beveled edges along two of its sides to improve the detector packing when placed in a ring geometry. The second detector utilizes a 50 mm by 50 mm by 15 mm, rectangular LYSO crystal coupled to a 64 channel, multi-anode PMT. It provides up to 15 layers of DOI information. The average intrinsic X, Y spatial resolution for the 8 mm thick, truncated crystal detector was 1.33 +/- 0.31 mm FWHM (45.6 mm by 46.6 mm useful imaging area). The average DOI resolution was 3.5 +/- 0.22 mm. The average intrinsic X, Y spatial resolution for the 15 mm thick crystal detector was 1.74 +/- 0.35 mm FWHM (44.6 mm by 44.6 mm useful imaging area). In addition, the average DOI spatial resolution for 56 test points spanning a 26.4 mm by 12.2 mm region of the crystal was 4.80 +/- 0.36 mm. We believe the 8 mm thick truncated crystal design is suitable for mouse imaging while the 15 mm thick crystal design is more suited for human organ specific imaging systems (e.g., breast and brain).

Abstract Image

Abstract Image

Abstract Image

新型连续微型晶体元件 (cMiCE) 探测器的几何形状。
连续微型晶体元件(cMiCE)探测器是高分辨率离散晶体设计的潜在低成本替代品。我们报告了两种具有相互作用深度(DOI)定位功能的 cMiCE PET 探测器设计的内在空间分辨率性能。第一个探测器采用 50 毫米 x 50 毫米 x 8 毫米的 LYSO 晶体,与 64 通道多阳极 PMT 相耦合。它提供 4 层 DOI 信息。晶体的两个侧面有斜边,以改善环形几何结构中探测器的封装。第二个探测器采用一个 50 毫米 x 50 毫米 x 15 毫米的矩形 LYSO 晶体,与一个 64 通道多阳极 PMT 相耦合。它可提供多达 15 层的 DOI 信息。厚度为 8 毫米的截断晶体探测器的平均 X、Y 本征空间分辨率为 1.33 +/- 0.31 毫米 FWHM(有效成像面积为 45.6 毫米 x 46.6 毫米)。平均 DOI 分辨率为 3.5 +/- 0.22 毫米。15 毫米厚的晶体探测器的平均 X、Y 本征空间分辨率为 1.74 +/- 0.35 毫米 FWHM(44.6 毫米 x 44.6 毫米有用成像区域)。此外,跨度为 26.4 毫米 x 12.2 毫米的 56 个测试点的平均 DOI 空间分辨率为 4.80 +/- 0.36 毫米。我们认为 8 毫米厚的截断晶体设计适合小鼠成像,而 15 毫米厚的晶体设计更适合人体器官特定成像系统(如乳腺和大脑)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信