500 ml of blood loss does not decrease non-invasive tissue oxygen saturation (StO2) as measured by near infrared spectroscopy - A hypothesis generating pilot study in healthy adult women.

Victor Jeger, Stephan M Jakob, Stefano Fontana, Martin Wolf, Heinz Zimmermann, Aristomenis K Exadaktylos
{"title":"500 ml of blood loss does not decrease non-invasive tissue oxygen saturation (StO2) as measured by near infrared spectroscopy - A hypothesis generating pilot study in healthy adult women.","authors":"Victor Jeger,&nbsp;Stephan M Jakob,&nbsp;Stefano Fontana,&nbsp;Martin Wolf,&nbsp;Heinz Zimmermann,&nbsp;Aristomenis K Exadaktylos","doi":"10.1186/1752-2897-4-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event.</p><p><strong>Methods: </strong>We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects.</p><p><strong>Results: </strong>Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase.</p><p><strong>Conclusion: </strong>StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.</p>","PeriodicalId":87652,"journal":{"name":"Journal of trauma management & outcomes","volume":"4 ","pages":"5"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1752-2897-4-5","citationCount":"60","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of trauma management & outcomes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1752-2897-4-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 60

Abstract

Background: The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event.

Methods: We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects.

Results: Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase.

Conclusion: StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.

Abstract Image

Abstract Image

Abstract Image

近红外光谱测定500ml失血量不会降低非侵入性组织氧饱和度(StO2)——在健康成年女性中进行的一项初步研究。
背景:创伤患者复苏的目标是实现足够的组织灌注。组织灌注的一个参数是组织氧饱和度(StO2),通过近红外光谱测量。使用市售设备,我们研究了标准化缺血事件后,健康志愿者500ml的临床相关失血是否可以通过StO2的变化来检测。方法:对20例健康女性献血者在献血前后进行3分钟的肱动脉闭塞术。连续测定鱼际隆起处StO2和总氧合组织血红蛋白(O2Hb)。10名健康志愿者以同样的方式进行评估,以检查不献血的重复血管闭塞是否具有时间依赖性效应。结果:献血使收缩压显著降低,但不影响静息StO2和O2Hb值。供血组血管闭塞试验反应无变化,而对照组再灌注期O2Hb恢复率有所增加。结论:在这种情况下,鱼际隆起处测量的StO2似乎对失血500ml不敏感。可能失血大于这个值可能会导致可检测到的变化,指导治疗医生。可检测变化的准确截点和重复血管闭塞试验的时间效应有待进一步探讨。直到现在还没有这样的数据存在。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书