{"title":"On cobalt-chrome frameworks in implant dentistry.","authors":"Lars Hjalmarsson","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cobalt-chrome (CoCr) alloys have been used in dentistry in decades but very little is known about their behavior and biological impact as framework materials in implant dentistry. Furthermore, few studies have evaluated and compared the clinical and radiological results of abutment and abutment-free implant treatment concepts.</p><p><strong>Aims: </strong>To investigate in vitro CoCr and commercially pure (CP) titanium frameworks regarding precision of fit, estimated material degradation and possible adverse cellular responses. In addition, to retrospectively evaluate the clinical and radiological five-year outcome of abutment-free porcelain-veneered CoCr prostheses compared to acrylic-veneered CP titanium prostheses, with or without abutments.</p><p><strong>Materials and methods: </strong>Paper I. Two groups of cast, sectioned and laser-welded frameworks were fabricated, either in a CoCr alloy or in CP titanium. A third group comprised computer numeric controlled (CNC) milled CP titanium frameworks. Measurements of fit were performed with a coordinate measuring machine. Paper IL Ion leakage from titanium implants, CoCr and CP titanium framework sections into artificial saliva was observed with mass spectrometry. Surface structures were registered with optical interferometry. Paper III. Viability of epithelial cells and fibroblasts cultured on CoCr and titanium specimens were evaluated with the Alamar Blue method. Specimen surface structures were registered with optical interferometry and cell morphology observed with SEM. Paper IV A test group (n = 40) comprised of patients treated with prostheses made at implant level in dental-porcelain veneered CoCr alloy (n = 15) or acrylic-veneered CP titanium (n = 25). A control group (n = 40) was provided with prostheses made at abutment level, in acrylic-veneered CNC-milled CP titanium. Clinical and radiological data were evaluated after five years.</p><p><strong>Results: </strong>Paper I. The transversal width decreased in CoCr frameworks, but increased in both groups of titanium frameworks. Less vertical distortions were present in the CNC-milled frameworks compared to the two other groups. Paper II. Significantly more cobalt ion leaked than titanium and chrome ions. Both framework sections and implants roughened after saliva exposure. Paper III. Both cell groups were more viable on titanium than on CoCr surfaces. The CoCr surfaces had a lower height deviation but were denser than the CP titanium surfaces. No major deviations from normal cell morphology were present. Paper IV. No significant differences in implant cumulative survival rates were demonstrated between the test and control groups after five years in function (98.6% and 97.6 %, respectively). No major differences in bone levels were demonstrated. Mucositis and veneer fracture were the most common complications in all groups.</p><p><strong>Conclusions: </strong>None of the frameworks presented a perfect, completely \"passive fit\". There were indications of active corrosive processes for both implants and framework materials. Epithelial cells and fibroblasts preferred titanium to CoCr surfaces. The clinical outcomes of implant level prostheses made of porcelain-veneered CoCr or acrylic-veneered titanium seem comparable to acrylic-veneered titanium prostheses made at abutment level.</p>","PeriodicalId":76572,"journal":{"name":"Swedish dental journal. Supplement","volume":" 201","pages":"3-83"},"PeriodicalIF":0.0000,"publicationDate":"2009-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Swedish dental journal. Supplement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cobalt-chrome (CoCr) alloys have been used in dentistry in decades but very little is known about their behavior and biological impact as framework materials in implant dentistry. Furthermore, few studies have evaluated and compared the clinical and radiological results of abutment and abutment-free implant treatment concepts.

Aims: To investigate in vitro CoCr and commercially pure (CP) titanium frameworks regarding precision of fit, estimated material degradation and possible adverse cellular responses. In addition, to retrospectively evaluate the clinical and radiological five-year outcome of abutment-free porcelain-veneered CoCr prostheses compared to acrylic-veneered CP titanium prostheses, with or without abutments.

Materials and methods: Paper I. Two groups of cast, sectioned and laser-welded frameworks were fabricated, either in a CoCr alloy or in CP titanium. A third group comprised computer numeric controlled (CNC) milled CP titanium frameworks. Measurements of fit were performed with a coordinate measuring machine. Paper IL Ion leakage from titanium implants, CoCr and CP titanium framework sections into artificial saliva was observed with mass spectrometry. Surface structures were registered with optical interferometry. Paper III. Viability of epithelial cells and fibroblasts cultured on CoCr and titanium specimens were evaluated with the Alamar Blue method. Specimen surface structures were registered with optical interferometry and cell morphology observed with SEM. Paper IV A test group (n = 40) comprised of patients treated with prostheses made at implant level in dental-porcelain veneered CoCr alloy (n = 15) or acrylic-veneered CP titanium (n = 25). A control group (n = 40) was provided with prostheses made at abutment level, in acrylic-veneered CNC-milled CP titanium. Clinical and radiological data were evaluated after five years.

Results: Paper I. The transversal width decreased in CoCr frameworks, but increased in both groups of titanium frameworks. Less vertical distortions were present in the CNC-milled frameworks compared to the two other groups. Paper II. Significantly more cobalt ion leaked than titanium and chrome ions. Both framework sections and implants roughened after saliva exposure. Paper III. Both cell groups were more viable on titanium than on CoCr surfaces. The CoCr surfaces had a lower height deviation but were denser than the CP titanium surfaces. No major deviations from normal cell morphology were present. Paper IV. No significant differences in implant cumulative survival rates were demonstrated between the test and control groups after five years in function (98.6% and 97.6 %, respectively). No major differences in bone levels were demonstrated. Mucositis and veneer fracture were the most common complications in all groups.

Conclusions: None of the frameworks presented a perfect, completely "passive fit". There were indications of active corrosive processes for both implants and framework materials. Epithelial cells and fibroblasts preferred titanium to CoCr surfaces. The clinical outcomes of implant level prostheses made of porcelain-veneered CoCr or acrylic-veneered titanium seem comparable to acrylic-veneered titanium prostheses made at abutment level.

钴铬框架在种植牙科中的应用。
背景:钴铬合金(CoCr)已经在牙科中使用了几十年,但对其作为种植牙科框架材料的行为和生物学影响知之甚少。此外,很少有研究评估和比较基牙和无基牙种植体治疗概念的临床和放射学结果。目的:研究体外CoCr和商业纯钛(CP)框架在拟合精度、估计材料降解和可能的不良细胞反应方面的差异。此外,回顾性评价无基牙瓷贴面CoCr假体与丙烯酸贴面CP钛假体在有无基牙情况下的临床和影像学5年预后。材料和方法:论文一:采用CoCr合金和CP钛制备了两组铸造、切片和激光焊接的框架。第三组包括计算机数控(CNC)铣削CP钛框架。配合测量用三坐标测量机进行。用质谱法观察钛植入物、CoCr和CP钛框架切片中IL离子渗漏到人工唾液中的情况。用光学干涉法对表面结构进行了记录。纸三世。用Alamar Blue法评价在CoCr和钛样品上培养的上皮细胞和成纤维细胞的活力。用光学干涉法记录了样品表面结构,用扫描电镜观察了细胞形态。试验组(n = 40)采用牙瓷贴面CoCr合金(n = 15)或丙烯酸贴面CP钛(n = 25)在种植体水平制作的假体。对照组(n = 40)采用亚克力贴面cnc铣削CP钛在基台水平制作假体。5年后对临床和放射学资料进行评估。CoCr框架的横向宽度减小,而两组钛框架的横向宽度均增加。与其他两组相比,cnc铣削框架中存在较少的垂直扭曲。论文二世。钴离子的泄漏量明显高于钛离子和铬离子。唾液暴露后,框架切片和植入物均变粗糙。纸三世。两组细胞在钛表面比在CoCr表面更有活力。CoCr表面的高度偏差较小,但密度大于CP钛表面。没有出现与正常细胞形态的重大偏差。试验组和对照组在功能恢复5年后种植体累积存活率无显著差异(分别为98.6%和97.6%)。骨水平没有明显差异。粘膜炎和骨贴面骨折是所有组中最常见的并发症。结论:没有一个框架是完美的,完全的“被动契合”。植入物和框架材料都有活性腐蚀过程的迹象。上皮细胞和成纤维细胞更喜欢钛而不是钴铬表面。瓷贴面CoCr或亚克力贴面钛与亚克力贴面钛在基台水平的临床效果相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信