{"title":"Multiscale time irreversibility of heartbeat at rest and during aerobic exercise.","authors":"Blanca De La Cruz Torres,&nbsp;José Naranjo Orellana","doi":"10.1007/s10558-009-9090-3","DOIUrl":null,"url":null,"abstract":"<p><p>The multiscale time irreversibility (MTI) involves the lack of consistency in the properties of a time series if one reverses the reading direction along the time. To analyze the RR time series at rest and during aerobic exercise through the MTI, both in healthy people and cardiac patients. The heartbeat signal was recorded beat to beat for 15 min at rest and 15 min while pedalling on a static bicycle in 10 healthy and active men (age 26.5 +/- 3.3 years; height 179.3 +/- 6.6 cm; weight 80.4 +/- 11.8 kg) and 10 cardiac patients (age 61.1 +/- 4.7 years, height 165.3 +/- 5.3 cm; weight 86.9 +/- 11.1 kg). The MTI was calculated through the asymmetry index (AI), defined as the sum of the values of asymmetry obtained for each scale from 1 to 10. The AI decreases significantly in healthy subjects from 0.51 +/- 0.28 at rest to 0.28 +/- 0.24 during exercise (P = 0.01) but not in cardiac patients (-0.2204 +/- 0.5097 at rest and 0.0848 +/- 0.1200 during exercise; P = 0.07). MTI distinguish adequately the four experimental situations because it can be considered as an index of the internal property of the signal in contrast to linear methods which are highly sensitive to external influences over the heart rhythm, particularly sympathetic and parasympathetic stimuli.</p>","PeriodicalId":55275,"journal":{"name":"Cardiovascular Engineering (dordrecht, Netherlands)","volume":"10 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2010-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s10558-009-9090-3","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Engineering (dordrecht, Netherlands)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10558-009-9090-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

The multiscale time irreversibility (MTI) involves the lack of consistency in the properties of a time series if one reverses the reading direction along the time. To analyze the RR time series at rest and during aerobic exercise through the MTI, both in healthy people and cardiac patients. The heartbeat signal was recorded beat to beat for 15 min at rest and 15 min while pedalling on a static bicycle in 10 healthy and active men (age 26.5 +/- 3.3 years; height 179.3 +/- 6.6 cm; weight 80.4 +/- 11.8 kg) and 10 cardiac patients (age 61.1 +/- 4.7 years, height 165.3 +/- 5.3 cm; weight 86.9 +/- 11.1 kg). The MTI was calculated through the asymmetry index (AI), defined as the sum of the values of asymmetry obtained for each scale from 1 to 10. The AI decreases significantly in healthy subjects from 0.51 +/- 0.28 at rest to 0.28 +/- 0.24 during exercise (P = 0.01) but not in cardiac patients (-0.2204 +/- 0.5097 at rest and 0.0848 +/- 0.1200 during exercise; P = 0.07). MTI distinguish adequately the four experimental situations because it can be considered as an index of the internal property of the signal in contrast to linear methods which are highly sensitive to external influences over the heart rhythm, particularly sympathetic and parasympathetic stimuli.

静息和有氧运动时心跳的多尺度时间不可逆性。
多尺度时间不可逆性(MTI)涉及到如果沿着时间反转读取方向,则时间序列的性质缺乏一致性。通过MTI分析健康人群和心脏病患者静息和有氧运动时的RR时间序列。记录10名健康活跃的男性(年龄26.5±3.3岁;身高179.3 +/- 6.6 cm;体重80.4 +/- 11.8 kg),心脏患者10例(年龄61.1 +/- 4.7岁,身高165.3 +/- 5.3 cm;重量86.9 +/- 11.1 kg)。MTI通过不对称指数(AI)计算,定义为从1到10的每个尺度获得的不对称值的总和。健康受试者的AI从休息时的0.51 +/- 0.28显著下降到运动时的0.28 +/- 0.24 (P = 0.01),而心脏病患者的AI则无显著下降(休息时为-0.2204 +/- 0.5097,运动时为0.0848 +/- 0.1200;P = 0.07)。MTI充分区分了四种实验情况,因为它可以被视为信号内部特性的指标,而线性方法对心律的外部影响高度敏感,特别是交感和副交感刺激。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信