{"title":"The reproducibility of measurements of intramuscular magnesium concentrations and muscle oxidative capacity using 31P MRS.","authors":"Kevin K McCully, Tiffany N Turner, Jason Langley, Qun Zhao","doi":"10.1186/1476-5918-8-5","DOIUrl":null,"url":null,"abstract":"<p><p>31P magnetic resonance spectroscopy (31P MRS) has been used to measure intramuscular magnesium concentrations and muscle metabolism. Abnormal intramuscular magnesium has been reported in several patient populations with suspected metabolic disorders. The purpose of this study was to evaluate our ability to measure intramuscular magnesium and muscle metabolism in the quadriceps muscles of healthy subjects, and to test whether these measurements were influenced by prior exercise. Twelve normal, healthy male volunteers were tested in a 3 Tesla magnet on four separate days. Resting [Mg2+] was calculated from the heights and frequency shifts of the phosphate, phosphocreatine and ATP peaks. Phosphocreatine (PCr) recovery kinetics were measured after 30-39 second bouts of isometric exercise. Thirty minutes prior to the 3rd test session the subjects completed a 2 hour treadmill walk at 40-60% of heart rate reserve. Resting [Mg2+] averaged 0.388 mM and had an interclass correlation coefficient between days (ICC) of 0.352. The mean end exercise PCr was 47.6% and the mean end exercise pH was 6.97. PCr recovery averaged 39 seconds (p = 0.892) and had an ICC of 0.819. Prior long duration exercise did not produce significant alterations in either PCr recovery kinetics or intracellular magnesium levels (p = 0.440). In conclusion, the reproducibility of Resting [Mg2+] was less than that of PCr recovery measurements, and may reflect the sensitivity of these measurements to phasing errors. In addition, prior exercise is unlikely to alter measurements of resting metabolites or muscle metabolism suggesting that rigorous control of physical activity prior to metabolic testing is unnecessary.</p>","PeriodicalId":84611,"journal":{"name":"Dynamic medicine : DM","volume":"8 ","pages":"5"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2801477/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dynamic medicine : DM","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1476-5918-8-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

31P magnetic resonance spectroscopy (31P MRS) has been used to measure intramuscular magnesium concentrations and muscle metabolism. Abnormal intramuscular magnesium has been reported in several patient populations with suspected metabolic disorders. The purpose of this study was to evaluate our ability to measure intramuscular magnesium and muscle metabolism in the quadriceps muscles of healthy subjects, and to test whether these measurements were influenced by prior exercise. Twelve normal, healthy male volunteers were tested in a 3 Tesla magnet on four separate days. Resting [Mg2+] was calculated from the heights and frequency shifts of the phosphate, phosphocreatine and ATP peaks. Phosphocreatine (PCr) recovery kinetics were measured after 30-39 second bouts of isometric exercise. Thirty minutes prior to the 3rd test session the subjects completed a 2 hour treadmill walk at 40-60% of heart rate reserve. Resting [Mg2+] averaged 0.388 mM and had an interclass correlation coefficient between days (ICC) of 0.352. The mean end exercise PCr was 47.6% and the mean end exercise pH was 6.97. PCr recovery averaged 39 seconds (p = 0.892) and had an ICC of 0.819. Prior long duration exercise did not produce significant alterations in either PCr recovery kinetics or intracellular magnesium levels (p = 0.440). In conclusion, the reproducibility of Resting [Mg2+] was less than that of PCr recovery measurements, and may reflect the sensitivity of these measurements to phasing errors. In addition, prior exercise is unlikely to alter measurements of resting metabolites or muscle metabolism suggesting that rigorous control of physical activity prior to metabolic testing is unnecessary.

Abstract Image

Abstract Image

Abstract Image

利用 31P MRS 测量肌肉内镁浓度和肌肉氧化能力的重现性。
31P 磁共振波谱(31P MRS)已被用于测量肌肉内的镁浓度和肌肉代谢。有报告称,一些疑似代谢紊乱患者的肌内镁含量异常。本研究的目的是评估我们测量健康受试者股四头肌肌内镁和肌肉新陈代谢的能力,并测试这些测量结果是否受之前运动的影响。我们在 3 特斯拉磁体中对 12 名正常、健康的男性志愿者分别进行了四天的测试。根据磷酸、磷酸肌酸和 ATP 峰的高度和频移计算出静息[Mg2+]。在 30-39 秒的等长运动后,对磷酸肌酸(PCr)的恢复动力学进行了测量。在第三次测试前 30 分钟,受试者以 40-60% 的心率储备完成了 2 小时的跑步机步行。静息[Mg2+]的平均值为 0.388 毫摩尔,日间类间相关系数(ICC)为 0.352。运动结束时的 PCr 平均值为 47.6%,运动结束时的 pH 平均值为 6.97。PCr 平均恢复时间为 39 秒(p = 0.892),ICC 为 0.819。之前的长时间运动不会对 PCr 恢复动力学或细胞内镁水平产生明显改变(p = 0.440)。总之,静息[Mg2+]的可重复性低于 PCr 恢复测量,这可能反映了这些测量对相位误差的敏感性。此外,之前的运动不太可能改变静息代谢物或肌肉代谢的测量结果,这表明在进行代谢测试之前没有必要严格控制运动量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书