Abbas Mgharbel, Hélène Delanoë-Ayari, Jean-Paul Rieu
{"title":"Measuring accurately liquid and tissue surface tension with a compression plate tensiometer.","authors":"Abbas Mgharbel, Hélène Delanoë-Ayari, Jean-Paul Rieu","doi":"10.2976/1.3116822","DOIUrl":null,"url":null,"abstract":"<p><p>Apparent tissue surface tension allows the quantification of cell-cell cohesion and was reported to be a powerful indicator for the cellular rearrangements that take place during embryonic development or for cancer progression. The measurement is realized with a parallel compression plate tensiometer using the capillary laws. Although it was introduced more than a decade ago, it is based on various geometrical or physical approximations. Surprisingly, these approximations have never been tested. Using a novel tensiometer, we compare the two currently used methods to measure tissue surface tension and propose a third one, based on a local polynomial fit (LPF) of the profile of compressed droplets or cell aggregates. We show the importance of measuring the contact angle between the plate and the dropaggregate to obtain real accurate measurement of surface tension when applying existing methods. We can suspect that many reported values of surface tension are greatly affected because of not handling this parameter properly. We show then the benefit of using the newly introduced LPF method, which is not dependent on this parameter. These findings are confirmed by generating numerically compressed droplet profiles and testing the robustness and the sensitivity to errors of the different methods.</p>","PeriodicalId":55056,"journal":{"name":"Hfsp Journal","volume":"3 3","pages":"213-21"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2976/1.3116822","citationCount":"55","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hfsp Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2976/1.3116822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2009/4/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 55
Abstract
Apparent tissue surface tension allows the quantification of cell-cell cohesion and was reported to be a powerful indicator for the cellular rearrangements that take place during embryonic development or for cancer progression. The measurement is realized with a parallel compression plate tensiometer using the capillary laws. Although it was introduced more than a decade ago, it is based on various geometrical or physical approximations. Surprisingly, these approximations have never been tested. Using a novel tensiometer, we compare the two currently used methods to measure tissue surface tension and propose a third one, based on a local polynomial fit (LPF) of the profile of compressed droplets or cell aggregates. We show the importance of measuring the contact angle between the plate and the dropaggregate to obtain real accurate measurement of surface tension when applying existing methods. We can suspect that many reported values of surface tension are greatly affected because of not handling this parameter properly. We show then the benefit of using the newly introduced LPF method, which is not dependent on this parameter. These findings are confirmed by generating numerically compressed droplet profiles and testing the robustness and the sensitivity to errors of the different methods.