[Analysis of abdominal organ motion using four-dimensional CT].

Mian Xi, Meng-Zhong Liu, Qiao-Qiao Li, Ling Cai, Li Zhang, Yong-Hong Hu
{"title":"[Analysis of abdominal organ motion using four-dimensional CT].","authors":"Mian Xi,&nbsp;Meng-Zhong Liu,&nbsp;Qiao-Qiao Li,&nbsp;Ling Cai,&nbsp;Li Zhang,&nbsp;Yong-Hong Hu","doi":"10.5732/cjc.009.10193","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>Accurate individualized measurement of organ motion is the premise of defining internal margin (IM) for abdominal malignancies. This study was to assess the three-dimensional abdominal organ motion caused by respiration using four-dimensional computed tomography (4DCT), and to analyze the association between the movement of diaphragm and abdominal organs.</p><p><strong>Methods: </strong>The 4DCT scans of 13 patients with hepatocellular carcinoma were analyzed, five of whom had para-aortic lymph node metastases. The liver, kidneys, pancreas, spleen, and para-aortic lymph nodes were contoured in all 10 respiratory phases of 4DCT scans. The 3D movement of diaphragm and organs was calculated and the relationship between the movement of diaphragm and abdominal organs was analyzed.</p><p><strong>Results: </strong>The average diaphragmatic movement was (10.3+/-4.0) mm with wide interpatient variations. Analysis of the center of the mass of abdominal organs revealed predominant cranio-caudal (CC) movement, with a mean of (10.1+/-3.9) mm for liver, (9.3+/-2.9) mm for left kidney, (9.6+/-4.1) mm for right kidney, (7.6+/-3.0) mm for pancreas, (10.6+/-3.3) mm for spleen, and (5.7+/-1.8) mm for para-aortic lymph nodes. The CC movement of the liver and the right kidney correlated well with the diaphragmatic movement, and no significant differences were observed. There was no significant correlation of the diaphragmatic movement to the CC movement of left kidney, pancreas and spleen. The movement of both kidneys was comparable, however, the movement of one kidney did not predict the movement of the contralateral one.</p><p><strong>Conclusions: </strong>The 4DCT scanning can accurately measure abdominal organ motion during whole respiration. The diaphragmatic mobility can approximate the CC movement of liver and right kidney, and the movement amplitude of para-aortic lymph nodes is much smaller than diaphragmatic mobility.</p>","PeriodicalId":7559,"journal":{"name":"Ai zheng = Aizheng = Chinese journal of cancer","volume":"28 9","pages":"989-93"},"PeriodicalIF":0.0000,"publicationDate":"2009-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ai zheng = Aizheng = Chinese journal of cancer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5732/cjc.009.10193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Background and objective: Accurate individualized measurement of organ motion is the premise of defining internal margin (IM) for abdominal malignancies. This study was to assess the three-dimensional abdominal organ motion caused by respiration using four-dimensional computed tomography (4DCT), and to analyze the association between the movement of diaphragm and abdominal organs.

Methods: The 4DCT scans of 13 patients with hepatocellular carcinoma were analyzed, five of whom had para-aortic lymph node metastases. The liver, kidneys, pancreas, spleen, and para-aortic lymph nodes were contoured in all 10 respiratory phases of 4DCT scans. The 3D movement of diaphragm and organs was calculated and the relationship between the movement of diaphragm and abdominal organs was analyzed.

Results: The average diaphragmatic movement was (10.3+/-4.0) mm with wide interpatient variations. Analysis of the center of the mass of abdominal organs revealed predominant cranio-caudal (CC) movement, with a mean of (10.1+/-3.9) mm for liver, (9.3+/-2.9) mm for left kidney, (9.6+/-4.1) mm for right kidney, (7.6+/-3.0) mm for pancreas, (10.6+/-3.3) mm for spleen, and (5.7+/-1.8) mm for para-aortic lymph nodes. The CC movement of the liver and the right kidney correlated well with the diaphragmatic movement, and no significant differences were observed. There was no significant correlation of the diaphragmatic movement to the CC movement of left kidney, pancreas and spleen. The movement of both kidneys was comparable, however, the movement of one kidney did not predict the movement of the contralateral one.

Conclusions: The 4DCT scanning can accurately measure abdominal organ motion during whole respiration. The diaphragmatic mobility can approximate the CC movement of liver and right kidney, and the movement amplitude of para-aortic lymph nodes is much smaller than diaphragmatic mobility.

腹部脏器运动的四维CT分析
背景与目的:准确的个体化器官运动测量是确定腹部恶性肿瘤内切区(IM)的前提。本研究利用四维计算机断层扫描(4DCT)评估呼吸引起的腹部器官三维运动,并分析膈肌运动与腹部器官的关系。方法:分析13例肝细胞癌患者的4DCT扫描,其中5例有主动脉旁淋巴结转移。在4DCT扫描的所有10个呼吸期中,肝脏、肾脏、胰腺、脾脏和主动脉旁淋巴结都被勾画出来。计算了横膈膜和脏器的三维运动,分析了横膈膜和腹部脏器的运动关系。结果:平均膈肌运动为(10.3+/-4.0)mm,患者间差异较大。腹部脏器肿块中心分析显示以颅尾部(CC)运动为主,肝脏(10.1+/-3.9)mm,左肾(9.3+/-2.9)mm,右肾(9.6+/-4.1)mm,胰腺(7.6+/-3.0)mm,脾脏(10.6+/-3.3)mm,主动脉旁淋巴结(5.7+/-1.8)mm。肝、右肾的CC运动与膈肌运动有良好的相关性,无显著性差异。膈肌运动与左肾、胰、脾CC运动无显著相关性。两个肾脏的运动是相似的,然而,一个肾脏的运动不能预测对侧肾脏的运动。结论:4DCT扫描能准确测量呼吸过程中腹部器官的运动。横膈膜的运动可近似于肝、右肾的CC运动,主动脉旁淋巴结的运动幅度远小于横膈膜的运动幅度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信