S S Randhawa, Baban K S Bansod, Anirudh K Singh, G Chand, A K Ganju
{"title":"Development of a photometric system for continuous flow analysis.","authors":"S S Randhawa, Baban K S Bansod, Anirudh K Singh, G Chand, A K Ganju","doi":"10.1155/S1463924603000087","DOIUrl":null,"url":null,"abstract":"<p><p>Most chemical analyses carried out in a clinical laboratory are colorimetric. An improved photometric system is described where a tungsten lamp is the light source, a photo-diode is the detector and a microcontroller 8051 is used for processing and displaying absorbances. The performance characteristics of the instrument are reported. The parameters investigated are photometric linearity, precision and instrumental drift.</p>","PeriodicalId":15248,"journal":{"name":"Journal of Automated Methods & Management in Chemistry","volume":"25 2","pages":"51-5"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/S1463924603000087","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Automated Methods & Management in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/S1463924603000087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Most chemical analyses carried out in a clinical laboratory are colorimetric. An improved photometric system is described where a tungsten lamp is the light source, a photo-diode is the detector and a microcontroller 8051 is used for processing and displaying absorbances. The performance characteristics of the instrument are reported. The parameters investigated are photometric linearity, precision and instrumental drift.