Automated Quality Assurance of Online NIR Analysers.

Kari Aaljoki
{"title":"Automated Quality Assurance of Online NIR Analysers.","authors":"Kari Aaljoki","doi":"10.1155/JAMMC.2005.44","DOIUrl":null,"url":null,"abstract":"<p><p>Modern NIR analysers produce valuable data for closed-loop process control and optimisation practically in real time. Thus it is highly important to keep them in the best possible shape. Quality assurance (QA) of NIR analysers is an interesting and complex issue because it is not only the instrument and sample handling that has to be monitored. At the same time, validity of prediction models has to be assured. A system for fully automated QA of NIR analysers is described. The system takes care of collecting and organising spectra from various instruments, relevant laboratory, and process management system (PMS) data. Validation of spectra is based on simple diagnostics values derived from the spectra. Predictions are validated against laboratory (LIMS) or other online analyser results (collected from PMS). The system features automated alarming, reporting, trending, and charting functions for major key variables for easy visual inspection. Various textual and graphical reports are sent to maintenance people through email. The software was written with Borland Delphi 7 Enterprise. Oracle and PMS ODBC interfaces were used for accessing LIMS and PMS data using appropriate SQL queries. It will be shown that it is possible to take actions even before the quality of predictions is seriously affected, thus maximising the overall uptime of the instrument.</p>","PeriodicalId":15248,"journal":{"name":"Journal of Automated Methods & Management in Chemistry","volume":"2005 ","pages":"44-9"},"PeriodicalIF":0.0000,"publicationDate":"2005-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/JAMMC.2005.44","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Automated Methods & Management in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/JAMMC.2005.44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Modern NIR analysers produce valuable data for closed-loop process control and optimisation practically in real time. Thus it is highly important to keep them in the best possible shape. Quality assurance (QA) of NIR analysers is an interesting and complex issue because it is not only the instrument and sample handling that has to be monitored. At the same time, validity of prediction models has to be assured. A system for fully automated QA of NIR analysers is described. The system takes care of collecting and organising spectra from various instruments, relevant laboratory, and process management system (PMS) data. Validation of spectra is based on simple diagnostics values derived from the spectra. Predictions are validated against laboratory (LIMS) or other online analyser results (collected from PMS). The system features automated alarming, reporting, trending, and charting functions for major key variables for easy visual inspection. Various textual and graphical reports are sent to maintenance people through email. The software was written with Borland Delphi 7 Enterprise. Oracle and PMS ODBC interfaces were used for accessing LIMS and PMS data using appropriate SQL queries. It will be shown that it is possible to take actions even before the quality of predictions is seriously affected, thus maximising the overall uptime of the instrument.

在线近红外分析仪的自动质量保证。
现代近红外分析仪可以实时为闭环过程控制和优化提供有价值的数据。因此,保持它们的最佳形状是非常重要的。近红外分析仪的质量保证(QA)是一个有趣而复杂的问题,因为它不仅仅是必须监控的仪器和样品处理。同时,也要保证预测模型的有效性。介绍了一种全自动近红外分析仪的质量保证系统。该系统负责收集和组织来自各种仪器、相关实验室和过程管理系统(PMS)数据的光谱。光谱的验证是基于从光谱中得到的简单诊断值。根据实验室(LIMS)或其他在线分析仪(从PMS收集)的结果验证预测。该系统具有自动报警,报告,趋势和图表功能的主要关键变量,便于目视检查。各种文本和图形报告通过电子邮件发送给维护人员。软件采用Borland Delphi 7 Enterprise编写。Oracle和PMS ODBC接口用于使用适当的SQL查询访问LIMS和PMS数据。它将表明,甚至在预测的质量受到严重影响之前采取行动是可能的,从而最大限度地延长仪器的整体正常运行时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信