A new test of resistance in the diagnosis of postero-superior rotator cuff tears.

La Chirurgia degli organi di movimento Pub Date : 2008-02-01 Epub Date: 2008-03-03 DOI:10.1007/s12306-007-0014-3
Stefano Gumina, Antonio Bertino, Giantony Di Giorgio, Franco Postacchini
{"title":"A new test of resistance in the diagnosis of postero-superior rotator cuff tears.","authors":"Stefano Gumina,&nbsp;Antonio Bertino,&nbsp;Giantony Di Giorgio,&nbsp;Franco Postacchini","doi":"10.1007/s12306-007-0014-3","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to assess the diagnostic accuracy of a new clinical test for the diagnosis of subacromial impingement and full thickness postero-superior rotator cuff tears. One hundred and twenty patients who underwent arthroscopic treatment for acromioplasty or cuff repair were previously submitted to a new test of resistance. The test is performed in the standing position with the involved arm in 90 degrees abduction, 20 degrees -30 degrees anteposition and in external rotation (as for full-can test). Thus, the patient was invited to follow the way of a spiral drawn on a drawing sheet for 20 turns; 1 turn = from the centre to the end of the spiral and vice versa (spiral width = 20 cm). The test was considered positive when the patient was not able to conclude it due to strength decrease or to shoulder pain. Sensitivity, specificity, positive and negative predictive values as well as diagnostic accuracy were calculated for our test of resistance. The test resulted scarcely reliable as detector of subacromial impingement and not very reliable as detector of small tear. When the test is positive there is a high probability that a subacromial disease exists; instead, when it is negative there is a high probability that the patient has not a large or massive cuff tear. The resistance test (Gum-Turn test) adds to our armamentarium of physical examination signs in patients with painful shoulder and furnishes further information on possible dimensions of tendinous tear.</p>","PeriodicalId":76085,"journal":{"name":"La Chirurgia degli organi di movimento","volume":"91 2","pages":"85-6"},"PeriodicalIF":0.0000,"publicationDate":"2008-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s12306-007-0014-3","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"La Chirurgia degli organi di movimento","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12306-007-0014-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2008/3/3 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

The aim of this study was to assess the diagnostic accuracy of a new clinical test for the diagnosis of subacromial impingement and full thickness postero-superior rotator cuff tears. One hundred and twenty patients who underwent arthroscopic treatment for acromioplasty or cuff repair were previously submitted to a new test of resistance. The test is performed in the standing position with the involved arm in 90 degrees abduction, 20 degrees -30 degrees anteposition and in external rotation (as for full-can test). Thus, the patient was invited to follow the way of a spiral drawn on a drawing sheet for 20 turns; 1 turn = from the centre to the end of the spiral and vice versa (spiral width = 20 cm). The test was considered positive when the patient was not able to conclude it due to strength decrease or to shoulder pain. Sensitivity, specificity, positive and negative predictive values as well as diagnostic accuracy were calculated for our test of resistance. The test resulted scarcely reliable as detector of subacromial impingement and not very reliable as detector of small tear. When the test is positive there is a high probability that a subacromial disease exists; instead, when it is negative there is a high probability that the patient has not a large or massive cuff tear. The resistance test (Gum-Turn test) adds to our armamentarium of physical examination signs in patients with painful shoulder and furnishes further information on possible dimensions of tendinous tear.

一种诊断肩后上袖撕裂的新阻力试验。
本研究的目的是评估一种诊断肩峰下撞击和全厚度后上肩袖撕裂的新临床试验的诊断准确性。120名接受关节镜治疗的肩峰成形术或袖带修复的患者先前接受了一项新的耐药性测试。测试在站立位置进行,受累手臂外展90度,前倾20度-30度,外旋(如全罐测试)。因此,患者被要求按照画在图纸上的螺旋的方式旋转20圈;1转=从中心到螺旋的末端,反之亦然(螺旋宽度= 20厘米)。当患者由于力量下降或肩部疼痛而无法得出结论时,该测试被认为是阳性的。计算耐药试验的敏感性、特异性、阳性预测值和阴性预测值以及诊断准确性。结果表明,作为肩峰下撞击的检测方法不太可靠,作为小撕裂的检测方法也不太可靠。当检测结果呈阳性时,很有可能存在肩峰下疾病;相反,当它是阴性时,很有可能患者没有大的或大量的袖带撕裂。阻力试验(Gum-Turn试验)增加了我们肩关节疼痛患者的体格检查征象,并提供了关于肌腱撕裂可能尺寸的进一步信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信