Using sequential injection analysis to improve system and data reliability of online methods: determination of ammonium and phosphate in coastal waters.

Carsten Frank, Friedhelm Schroeder
{"title":"Using sequential injection analysis to improve system and data reliability of online methods: determination of ammonium and phosphate in coastal waters.","authors":"Carsten Frank,&nbsp;Friedhelm Schroeder","doi":"10.1155/2007/49535","DOIUrl":null,"url":null,"abstract":"<p><p>This article summarises the advantages of the sequential injection analysis (SIA) for the online determination of nutrients in coastal waters. It concentrates on techniques to improve the reliability of the gained data by continuously monitoring one or more standards and on the advantages of online standard additions and offline determination of manually collected samples with the online SIA system. These measures are advantageous during method development and validation and can be used to verify the system performance on a regular base to reduce the amount of erroneous results. No changes in the flow system are necessary and the sample throughput is only slightly reduced. These techniques have been applied to a SIA system which is able to simultaneously determine ammonium and phosphate at a rate of more than 100 samples per hour each and detection limits (3sigma) of 0.06 muM and 0.05 muM. Results from a campaign in summer 2005 are shown.</p>","PeriodicalId":15248,"journal":{"name":"Journal of Automated Methods & Management in Chemistry","volume":"2007 ","pages":"49535"},"PeriodicalIF":0.0000,"publicationDate":"2007-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2007/49535","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Automated Methods & Management in Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2007/49535","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

This article summarises the advantages of the sequential injection analysis (SIA) for the online determination of nutrients in coastal waters. It concentrates on techniques to improve the reliability of the gained data by continuously monitoring one or more standards and on the advantages of online standard additions and offline determination of manually collected samples with the online SIA system. These measures are advantageous during method development and validation and can be used to verify the system performance on a regular base to reduce the amount of erroneous results. No changes in the flow system are necessary and the sample throughput is only slightly reduced. These techniques have been applied to a SIA system which is able to simultaneously determine ammonium and phosphate at a rate of more than 100 samples per hour each and detection limits (3sigma) of 0.06 muM and 0.05 muM. Results from a campaign in summer 2005 are shown.

Abstract Image

Abstract Image

Abstract Image

应用序次注射分析提高近岸水体中铵、磷酸盐在线测定方法的系统和数据可靠性。
本文综述了连续注射分析法(SIA)用于沿海水域营养物质在线测定的优点。它侧重于通过连续监测一个或多个标准来提高所获得数据可靠性的技术,以及在线添加标准和离线确定在线SIA系统手动采集样品的优势。这些措施在方法开发和验证期间是有利的,并且可以用于定期验证系统性能,以减少错误结果的数量。不需要对流程系统进行任何更改,样品吞吐量仅略有降低。这些技术已应用于SIA系统,该系统能够以每小时超过100个样品的速率同时测定铵和磷酸盐,检测限(3 σ)为0.06 muM和0.05 muM。图为2005年夏季一次活动的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信