Comparative analysis of different scintigraphic approaches to assess pulmonary ventilation.

J Magnant, L Vecellio, M de Monte, D Grimbert, C Valat, E Boissinot, D Guilloteau, E Lemarié, P Diot
{"title":"Comparative analysis of different scintigraphic approaches to assess pulmonary ventilation.","authors":"J Magnant,&nbsp;L Vecellio,&nbsp;M de Monte,&nbsp;D Grimbert,&nbsp;C Valat,&nbsp;E Boissinot,&nbsp;D Guilloteau,&nbsp;E Lemarié,&nbsp;P Diot","doi":"10.1089/jam.2006.19.148","DOIUrl":null,"url":null,"abstract":"<p><p>A study was carried out to investigate the predictive value of 81-metastable-krypton (81mKr) distribution, high-size 99-metastable-technetium (99mTc) aerosol deposition and low-size 99mTc aerosol (Technegas) deposition on the pulmonary ventilation evaluated by 133-xenon (133Xe) lung scintigraphy, and to assess the correlation between the 81mKr distribution, the 99mTc aerosols deposition, and the respiratory parameters of patients with chronic obstructive pulmonary disease (COPD). Twenty COPD patients were included. The 81mKr, 133Xe, and 99mTc aerosol lung scintigraphies were successively carried out. The 81mKr distribution and 99mTc deposition were compared to the 133Xe distribution at equilibrium and to the 133Xe clearance. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 81mKr and Technegas lung scintigraphies to detect alterations in ventilation revealed by 133Xe were defined. The 81mKr distribution and 99mTc deposition according to respiratory parameters were described using a principal component analysis. Compared to 133Xe distribution, a significantly higher distribution of 81mKr in the upper parts of the lungs in the more severe patients (p = 0.05), a significantly higher deposition of Technegas in the lower parts of the lungs (p = 0.0008), and a significantly higher deposition in the central parts of the high-size 99mTc aerosol were observed (p = 0.0001). The PPV and the NPV were, respectively, 0.54 and 0.58 for 81mKr and 0.54 and 0.55 for Technegas. There was a significant negative correlation between 81mKr distribution and 133Xe clearance (p = 0.0001) between Technegas deposition and 133Xe clearance (p = 0.0007), and between 99mTc diethylene-triamino-penta-acetate (DTPA) deposition and 133Xe clearance (p = 0.001). Both the 81mKr peripheral distribution and Technegas peripheral deposition correlated negatively with increased obstruction, as measured by forced expiratory volume in 1 sec (FEV1). Peripheral deposition of the high-size 99mTc aerosol deposition correlated with the inspiration/expiration time ratio. In conclusion, 81mKr and 99mTc aerosols' lung scintigraphies do not reflect exactly the pulmonary ventilation as measured by 133Xe scintigraphy.</p>","PeriodicalId":14878,"journal":{"name":"Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine","volume":"19 2","pages":"148-59"},"PeriodicalIF":0.0000,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/jam.2006.19.148","citationCount":"32","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/jam.2006.19.148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32

Abstract

A study was carried out to investigate the predictive value of 81-metastable-krypton (81mKr) distribution, high-size 99-metastable-technetium (99mTc) aerosol deposition and low-size 99mTc aerosol (Technegas) deposition on the pulmonary ventilation evaluated by 133-xenon (133Xe) lung scintigraphy, and to assess the correlation between the 81mKr distribution, the 99mTc aerosols deposition, and the respiratory parameters of patients with chronic obstructive pulmonary disease (COPD). Twenty COPD patients were included. The 81mKr, 133Xe, and 99mTc aerosol lung scintigraphies were successively carried out. The 81mKr distribution and 99mTc deposition were compared to the 133Xe distribution at equilibrium and to the 133Xe clearance. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 81mKr and Technegas lung scintigraphies to detect alterations in ventilation revealed by 133Xe were defined. The 81mKr distribution and 99mTc deposition according to respiratory parameters were described using a principal component analysis. Compared to 133Xe distribution, a significantly higher distribution of 81mKr in the upper parts of the lungs in the more severe patients (p = 0.05), a significantly higher deposition of Technegas in the lower parts of the lungs (p = 0.0008), and a significantly higher deposition in the central parts of the high-size 99mTc aerosol were observed (p = 0.0001). The PPV and the NPV were, respectively, 0.54 and 0.58 for 81mKr and 0.54 and 0.55 for Technegas. There was a significant negative correlation between 81mKr distribution and 133Xe clearance (p = 0.0001) between Technegas deposition and 133Xe clearance (p = 0.0007), and between 99mTc diethylene-triamino-penta-acetate (DTPA) deposition and 133Xe clearance (p = 0.001). Both the 81mKr peripheral distribution and Technegas peripheral deposition correlated negatively with increased obstruction, as measured by forced expiratory volume in 1 sec (FEV1). Peripheral deposition of the high-size 99mTc aerosol deposition correlated with the inspiration/expiration time ratio. In conclusion, 81mKr and 99mTc aerosols' lung scintigraphies do not reflect exactly the pulmonary ventilation as measured by 133Xe scintigraphy.

不同扫描入路评估肺通气的比较分析。
本研究探讨81亚稳氪(81mKr)分布、高粒径99亚稳锝(99mTc)气溶胶沉积和低粒径99mTc气溶胶(Technegas)沉积对133氙(133Xe)肺闪烁显像评价肺通气的预测价值,并探讨81mKr分布、99mTc气溶胶沉积与慢性阻塞性肺疾病(COPD)患者呼吸参数的相关性。纳入20例COPD患者。先后进行了81mKr、133Xe和99mTc气溶胶肺闪烁。将81mKr分布和99mTc沉积与平衡态133Xe分布和133Xe间隙进行了比较。定义了81mKr和Technegas肺显像检测133Xe显示的通气改变的敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)。用主成分分析方法描述了81mKr的分布和99mTc的沉积。与133Xe的分布相比,重症患者肺上部81mKr的分布显著增加(p = 0.05),肺下部Technegas的沉积显著增加(p = 0.0008),大粒径99mTc气溶胶中部沉积显著增加(p = 0.0001)。81mKr的PPV和NPV分别为0.54和0.58,Technegas的PPV和NPV分别为0.54和0.55。81mKr分布与133Xe清除率之间呈显著负相关(p = 0.0001), Technegas沉积与133Xe清除率之间呈显著负相关(p = 0.0007), 99mTc DTPA沉积与133Xe清除率之间呈显著负相关(p = 0.001)。通过1秒用力呼气量(FEV1)测量,81mKr外周分布和Technegas外周沉积与梗阻加重呈负相关。99mTc大粒径气溶胶周边沉降与吸入/呼气时间比相关。综上所述,81mKr和99mTc气溶胶的肺闪烁图不能准确反映133Xe闪烁图测量的肺通气。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信