IT-driven patient safety at the heart of radiology service improvement.

Michael Moores, David Anwyl, Paul Connolly, Lynn Anslow, Helen Monaghan, David Hughes, Matthew Ward, Paul Charnock
{"title":"IT-driven patient safety at the heart of radiology service improvement.","authors":"Michael Moores,&nbsp;David Anwyl,&nbsp;Paul Connolly,&nbsp;Lynn Anslow,&nbsp;Helen Monaghan,&nbsp;David Hughes,&nbsp;Matthew Ward,&nbsp;Paul Charnock","doi":"10.1080/14639230500299097","DOIUrl":null,"url":null,"abstract":"<p><p>Patient safety is a fundamental requirement of modern health-care systems and the application of information technology (IT) to this activity should have improvements in the area as one of its goals. Indeed, ensuring that the diagnostic IT strategy is optimized, for example, the use of IT in service redesign or data analysis, forms one of the main platforms for the National Framework for Service Improvement in Radiology. This paper presents both the concept behind and the results of a project that has been under way in the UK involving St Helens and Knowsley NHS Trust and IRS Ltd concerned with implementing effective IT-driven scientific support in the field of medical radiation protection. Locally developed software is employed in assessing, managing, and analysing patient dose data arising from X-ray examinations performed in the busy department of a large district general hospital (DGH). Such data are analysed in a variety of ways, for example, over time and according to location (department or X-ray room). This analysis not only provides a measure of performance against nationally agreed dose reference levels (DRLs) but also enables a detailed analysis of any variations as well as the establishment of local DRLs (performance indicators). This process provides quantitative input to management strategies aimed at service improvement. Such strategies are geared towards the support of the Ionizing Radiations (Medical Exposures) Regulations 2000 as well as implementation of quality-management principles at the heart of radiology practices.</p>","PeriodicalId":80069,"journal":{"name":"Medical informatics and the Internet in medicine","volume":"30 2","pages":"123-33"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/14639230500299097","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical informatics and the Internet in medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14639230500299097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Patient safety is a fundamental requirement of modern health-care systems and the application of information technology (IT) to this activity should have improvements in the area as one of its goals. Indeed, ensuring that the diagnostic IT strategy is optimized, for example, the use of IT in service redesign or data analysis, forms one of the main platforms for the National Framework for Service Improvement in Radiology. This paper presents both the concept behind and the results of a project that has been under way in the UK involving St Helens and Knowsley NHS Trust and IRS Ltd concerned with implementing effective IT-driven scientific support in the field of medical radiation protection. Locally developed software is employed in assessing, managing, and analysing patient dose data arising from X-ray examinations performed in the busy department of a large district general hospital (DGH). Such data are analysed in a variety of ways, for example, over time and according to location (department or X-ray room). This analysis not only provides a measure of performance against nationally agreed dose reference levels (DRLs) but also enables a detailed analysis of any variations as well as the establishment of local DRLs (performance indicators). This process provides quantitative input to management strategies aimed at service improvement. Such strategies are geared towards the support of the Ionizing Radiations (Medical Exposures) Regulations 2000 as well as implementation of quality-management principles at the heart of radiology practices.

it驱动的患者安全是放射服务改进的核心。
病人安全是现代保健系统的一项基本要求,信息技术在这方面的应用应作为其目标之一。事实上,确保诊断IT策略得到优化,例如,在服务重新设计或数据分析中使用IT,形成了国家放射学服务改进框架的主要平台之一。本文介绍了背后的概念和已经在英国进行的一个项目的结果,该项目涉及圣海伦斯和诺斯利NHS信托和IRS有限公司,涉及在医疗辐射防护领域实施有效的it驱动的科学支持。本地开发的软件用于评估、管理和分析在一家大型地区综合医院(DGH)繁忙的部门进行的x射线检查中产生的患者剂量数据。这些数据以多种方式进行分析,例如,根据时间和地点(科室或x光室)。这种分析不仅根据国家商定的剂量参考水平(drl)提供了一种绩效衡量标准,而且能够对任何变化进行详细分析,并建立当地的剂量参考水平(绩效指标)。这一过程为旨在改善服务的管理策略提供了定量的输入。这些战略旨在支持《2000年电离辐射(医疗照射)条例》,并实施作为放射学实践核心的质量管理原则。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信