High-resolution thickness maps of corrosion using SH1 guided wave tomography.

IF 3
Andreas A E Zimmermann, Peter Huthwaite, Brian Pavlakovic
{"title":"High-resolution thickness maps of corrosion using SH1 guided wave tomography.","authors":"Andreas A E Zimmermann,&nbsp;Peter Huthwaite,&nbsp;Brian Pavlakovic","doi":"10.1098/rspa.2020.0380","DOIUrl":null,"url":null,"abstract":"<p><p>Quantifying corrosion damage is vital for the petrochemical industry, and guided wave tomography can provide thickness maps of such regions by transmitting guided waves through these areas and capturing the scattering information using arrays. The dispersive nature of the guided waves enables a reconstruction of wave velocity to be converted into thickness. However, existing approaches have been shown to be limited in in-plane resolution, significantly short of that required to accurately image a defect target of three times the wall thickness (i.e. 3 T) in each in-plane direction. This is largely due to the long wavelengths of the fundamental modes commonly used, being around 4 T for both A0 and S0 at the typical operation points. In this work, the suitability of the first-order shear-horizontal guided wave mode, SH1, has been investigated to improve the resolution limit. The wavelength at the desired operating point is significantly shorter, enabling an improvement in resolution of around 2.4 times. This is first verified by realistic finite-element simulations and then validated by experimental results, confirming the improved resolution limit can now allow defects of maximum extent 3T-by-3T to be reliably detected and sized, i.e. a long-pursued goal of guided wave tomography has been achieved.</p>","PeriodicalId":520758,"journal":{"name":"Proceedings. Mathematical, physical, and engineering sciences","volume":" ","pages":"20200380"},"PeriodicalIF":3.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7897635/pdf/rspa20200380.pdf","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. Mathematical, physical, and engineering sciences","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1098/rspa.2020.0380","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Quantifying corrosion damage is vital for the petrochemical industry, and guided wave tomography can provide thickness maps of such regions by transmitting guided waves through these areas and capturing the scattering information using arrays. The dispersive nature of the guided waves enables a reconstruction of wave velocity to be converted into thickness. However, existing approaches have been shown to be limited in in-plane resolution, significantly short of that required to accurately image a defect target of three times the wall thickness (i.e. 3 T) in each in-plane direction. This is largely due to the long wavelengths of the fundamental modes commonly used, being around 4 T for both A0 and S0 at the typical operation points. In this work, the suitability of the first-order shear-horizontal guided wave mode, SH1, has been investigated to improve the resolution limit. The wavelength at the desired operating point is significantly shorter, enabling an improvement in resolution of around 2.4 times. This is first verified by realistic finite-element simulations and then validated by experimental results, confirming the improved resolution limit can now allow defects of maximum extent 3T-by-3T to be reliably detected and sized, i.e. a long-pursued goal of guided wave tomography has been achieved.

使用SH1导波层析成像的高分辨率腐蚀厚度图。
对石化行业来说,腐蚀损伤的量化是至关重要的,而导波层析成像可以通过将导波传输到这些区域,并使用阵列捕获散射信息,从而提供这些区域的厚度图。导波的色散特性使波速的重建能够转化为厚度。然而,现有的方法已被证明在面内分辨率上是有限的,明显低于在每个面内方向上精确成像三倍壁厚(即3t)的缺陷目标所需的分辨率。这主要是由于通常使用的基本模式的长波长,在典型操作点A0和S0的波长都在4 T左右。本文研究了一阶剪切-水平导波模式SH1的适用性,以提高分辨率极限。所需工作点处的波长明显更短,使分辨率提高约2.4倍。首先通过现实的有限元模拟验证了这一点,然后通过实验结果验证了这一点,证实了改进的分辨率极限现在可以可靠地检测和确定最大范围3t × 3t的缺陷,即实现了导波层析成像长期追求的目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书