Changes in magnetocardiogram patterns of infarcted-reperfused myocardium after injection of superparamagnetic contrast media.

A Brazdeikis, C W Chu, P Cherukuri, S Litovsky, M Naghavi
{"title":"Changes in magnetocardiogram patterns of infarcted-reperfused myocardium after injection of superparamagnetic contrast media.","authors":"A Brazdeikis,&nbsp;C W Chu,&nbsp;P Cherukuri,&nbsp;S Litovsky,&nbsp;M Naghavi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The changes in spatio-temporal patterns of magnetocardiograms were investigated following injection of superparamagnetic iron-oxide (SPIO) nanoparticles using a dog model of ischemia/reperfusion. Acute myocardial infarction was induced by ligation of the left anterior descending coronary in two anesthetized open-chest dogs. Following 60 min coronary occlusion and 30 min reperfusion, dogs were subjected to injections of SPIO at a dose of 0.56 mg Fe/kg using a catheter inserted into the left atrium. Magnetocardiograms were measured before coronary occlusion, 15 min after reperfusion and immediately after administration of the SPIO. Magnetic field maps of early reperfused myocardium showed spatio-temporal field distributions consistent with anterior myocardial infarction. Magnetic field distribution measured after injection of SPIO revealed additional spatio-temporal features most prominent during ventricular repolarization due to augmentation/fragmentation of the ST-segment detected at several sensor locations. No significant differences in MCG patterns were noted following contrast agent injections in a dog without coronary occlusion. In conclusion, preliminary experimental evidence appears to support the notion that superparamagnetic contrast agents increase the sensitivity of standard MCG and may have an important implication for magnetocardiography in the assessment of regional myocardial ischemia, infarction and perfusion.</p>","PeriodicalId":83814,"journal":{"name":"Neurology & clinical neurophysiology : NCN","volume":"2004 ","pages":"16"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurology & clinical neurophysiology : NCN","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The changes in spatio-temporal patterns of magnetocardiograms were investigated following injection of superparamagnetic iron-oxide (SPIO) nanoparticles using a dog model of ischemia/reperfusion. Acute myocardial infarction was induced by ligation of the left anterior descending coronary in two anesthetized open-chest dogs. Following 60 min coronary occlusion and 30 min reperfusion, dogs were subjected to injections of SPIO at a dose of 0.56 mg Fe/kg using a catheter inserted into the left atrium. Magnetocardiograms were measured before coronary occlusion, 15 min after reperfusion and immediately after administration of the SPIO. Magnetic field maps of early reperfused myocardium showed spatio-temporal field distributions consistent with anterior myocardial infarction. Magnetic field distribution measured after injection of SPIO revealed additional spatio-temporal features most prominent during ventricular repolarization due to augmentation/fragmentation of the ST-segment detected at several sensor locations. No significant differences in MCG patterns were noted following contrast agent injections in a dog without coronary occlusion. In conclusion, preliminary experimental evidence appears to support the notion that superparamagnetic contrast agents increase the sensitivity of standard MCG and may have an important implication for magnetocardiography in the assessment of regional myocardial ischemia, infarction and perfusion.

注射超顺磁造影剂后梗死再灌注心肌的心磁图变化。
采用犬缺血再灌注模型,观察超顺磁性氧化铁纳米颗粒注射后心脏磁图时空格局的变化。采用左冠状动脉前降段结扎术对两只麻醉开胸犬进行急性心肌梗死的观察。冠状动脉闭塞60 min,再灌注30 min后,通过左心房导管注射0.56 mg Fe/kg的SPIO。分别在冠脉闭塞前、再灌注后15分钟和注射SPIO后立即测量心磁图。早期再灌注心肌的磁场图显示出与心肌梗死前期一致的时空场分布。注射SPIO后测量的磁场分布揭示了额外的时空特征,这些特征在心室复极期间最为突出,这是由于在多个传感器位置检测到st段的增强/碎片化。在没有冠状动脉闭塞的狗注射造影剂后,MCG模式没有显着差异。总之,初步的实验证据似乎支持超顺磁造影剂增加标准MCG敏感性的观点,并可能对心脏磁图评估局部心肌缺血、梗死和灌注具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信