Argos 500: operation of a helmet vector-MEG.

A Pasquarelli, R Rossi, M De Melis, L Marzetti, A Trebeschi, H-P Müller, S N Erné
{"title":"Argos 500: operation of a helmet vector-MEG.","authors":"A Pasquarelli,&nbsp;R Rossi,&nbsp;M De Melis,&nbsp;L Marzetti,&nbsp;A Trebeschi,&nbsp;H-P Müller,&nbsp;S N Erné","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We here describe the MEG system recently installed at the University of Ulm; it is specifically designed for clinical application and routine use, to allow investigation of a large number of patients per day. To reach this goal, the system design meets the requirements of reliability, high field sensitivity, minimal set-up time before each measurement and an easy-to-handle user interface. The sensor system consists of a 163 vector-magnetometers array oriented and located in a suitable way to cover the whole head of the patient. Four additional triplets are available as references to arrange software gradiometers. The helmet shaped sensor system is positioned to accommodate the patient in a supine position. Simultaneously to the MEG, there are 64 EEG channels. Other relevant patient information can be recorded up to a total number of 660 acquisition channels. Noise level of a single magnetometer is about 5 fT/square root of Hz. Maximum sampling rate is 4200 Hz.</p>","PeriodicalId":83814,"journal":{"name":"Neurology & clinical neurophysiology : NCN","volume":"2004 ","pages":"97"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurology & clinical neurophysiology : NCN","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We here describe the MEG system recently installed at the University of Ulm; it is specifically designed for clinical application and routine use, to allow investigation of a large number of patients per day. To reach this goal, the system design meets the requirements of reliability, high field sensitivity, minimal set-up time before each measurement and an easy-to-handle user interface. The sensor system consists of a 163 vector-magnetometers array oriented and located in a suitable way to cover the whole head of the patient. Four additional triplets are available as references to arrange software gradiometers. The helmet shaped sensor system is positioned to accommodate the patient in a supine position. Simultaneously to the MEG, there are 64 EEG channels. Other relevant patient information can be recorded up to a total number of 660 acquisition channels. Noise level of a single magnetometer is about 5 fT/square root of Hz. Maximum sampling rate is 4200 Hz.

Argos 500:头盔矢量meg的操作。
我们在这里介绍最近在乌尔姆大学安装的MEG系统;它是专门为临床应用和日常使用而设计的,允许每天对大量患者进行调查。为了实现这一目标,系统设计满足可靠性、高现场灵敏度、每次测量前最小的设置时间和易于操作的用户界面的要求。传感器系统由163个矢量磁力计阵列组成,定向并以适当的方式覆盖患者的整个头部。另外四个三联体可作为安排软件梯度计的参考。头盔形状的传感器系统的定位,以适应病人在仰卧位。与脑磁图同步,有64个脑电信号通道。其他相关的患者信息可以记录多达660个采集通道。单个磁强计的噪声级约为5 fT/ Hz的平方根。最大采样率为4200hz。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信