All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems.

Swedish dental journal. Supplement Pub Date : 2005-01-01
Per Vult von Steyern
{"title":"All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems.","authors":"Per Vult von Steyern","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The development of refined, tougher, and stronger ceramic core materials in recent years has led to the wider use of new, strong all-ceramic systems based on oxide ceramics. Results from in-vitro studies investigating the use of oxide ceramics in shorter all-ceramic fixed partial dentures (FPDs) have been positive, but clinical studies and additional in-vitro studies are needed to confirm the advisability of such procedures.</p><p><strong>Aims: </strong>One aim of this thesis was to investigate whether alumina-based and zirconia-based material systems are adequate for use in shorter (< or = five-unit) FPDs and to evaluate the clinical results. Additional aims were to investigate how to achieve optimal fracture strength in an all-ceramic FPD by varying the try-in procedure, the cervical shape of the abutments, and the support of the FPD (abutment teeth or dental implants). The final aim was to compare the strength of a zirconia material system with that of an alumina equivalent with known long-term clinical performance.</p><p><strong>Materials and methods: </strong>Two clinical studies investigating one alumina-based and one zirconia-based material system were performed. Twenty posterior, three-unit FPDs (glass-infiltrated alumina) were followed for 5 years and 20 three-five-unit FPDs (HIP zirconia) for 2 years. Long-term follow-ups were made after 11 +/-1 (glass-infiltrated alumina) and 3 years (HIP zirconia). In three in-vitro studies, the following variables were investigated: (1a) the flexural strength of porcelain specimens depending on whether they were exposed to saliva before the glaze firing (n=20) or first after the glaze firing (n=20), (1b) the fracture strength of three-unit all-ceramic FPDs (glass-infiltrated alumina) supported by abutments prepared with cervical shoulder preparations (n=9) and abutments with cervical chamfer preparations (n=9), (2) the fracture strength of crowns (n=30) made of a zirconia material system (densely sintered zirconia) and of crowns (n=30) of an alumina material system (densely sintered alumina) that had undergone three different pre-treatment modalities (water storage only; water storage and cyclic pre-loading; water storage, cyclic pre-loading, and thermocycling), (3) the fracture strength of all-ceramic FPDs (densely sintered alumina) supported by simulated teeth (n=12) or by dental implants (n=12).</p><p><strong>Results: </strong>The success rate of the clinical alumina study was 90% after 5 years. Six (+/-1) years later (after a total of 11 +/-1 years), the success/survival rate was 65%. In the second clinical study, the success rates of the 2- and 3-year follow-ups were 100%. In the three in-vitro studies, the following results were found: (1a) the mean flexural strength of the specimens in the group that was exposed to saliva first after glazing was significantly higher (P < 0.001) than that of the specimens in the group that was exposed to saliva before glazing, (1b) the FPDs luted on shoulder preparations resisted higher loads than the FPDs luted on chamfer preparations (P = 0.051), 2) total fractures were more frequent in the alumina than in the zirconia group (P < 0.001), 3) FPDs loaded on implants resisted higher loads (mean = 604 N, SD=184 N ) than FPDs loaded on abutment teeth (mean= 378 N, SD=152 N, P = 0.003).</p><p><strong>Conclusions: </strong>This thesis justifies the use of shorter alumina- (< or = three-unit) and zirconia-based (< or = five-unit) FPDs as the clinical results are acceptable. The clinical performance of alumina is, however, not as good as that of comparable high-gold alloy based porcelain-fused-to-metal FPDs concerning fracture resistance. Within the limitations of the in-vitro studies: Saliva exposure of porcelain before glaze firing should be avoided to optimize the strength of the porcelain. Shoulder preparations can be beneficial for the strength of all-ceramic FPDs compared to chamfer preparations, as can support by dental implants compared to abutment teeth. The fracture mode of alumina crowns (total fractures) differs from that of zirconia crowns (veneer fractures), suggesting that the zirconia core is stronger than the alumina core.</p>","PeriodicalId":76572,"journal":{"name":"Swedish dental journal. Supplement","volume":" 173","pages":"1-69"},"PeriodicalIF":0.0000,"publicationDate":"2005-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Swedish dental journal. Supplement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The development of refined, tougher, and stronger ceramic core materials in recent years has led to the wider use of new, strong all-ceramic systems based on oxide ceramics. Results from in-vitro studies investigating the use of oxide ceramics in shorter all-ceramic fixed partial dentures (FPDs) have been positive, but clinical studies and additional in-vitro studies are needed to confirm the advisability of such procedures.

Aims: One aim of this thesis was to investigate whether alumina-based and zirconia-based material systems are adequate for use in shorter (< or = five-unit) FPDs and to evaluate the clinical results. Additional aims were to investigate how to achieve optimal fracture strength in an all-ceramic FPD by varying the try-in procedure, the cervical shape of the abutments, and the support of the FPD (abutment teeth or dental implants). The final aim was to compare the strength of a zirconia material system with that of an alumina equivalent with known long-term clinical performance.

Materials and methods: Two clinical studies investigating one alumina-based and one zirconia-based material system were performed. Twenty posterior, three-unit FPDs (glass-infiltrated alumina) were followed for 5 years and 20 three-five-unit FPDs (HIP zirconia) for 2 years. Long-term follow-ups were made after 11 +/-1 (glass-infiltrated alumina) and 3 years (HIP zirconia). In three in-vitro studies, the following variables were investigated: (1a) the flexural strength of porcelain specimens depending on whether they were exposed to saliva before the glaze firing (n=20) or first after the glaze firing (n=20), (1b) the fracture strength of three-unit all-ceramic FPDs (glass-infiltrated alumina) supported by abutments prepared with cervical shoulder preparations (n=9) and abutments with cervical chamfer preparations (n=9), (2) the fracture strength of crowns (n=30) made of a zirconia material system (densely sintered zirconia) and of crowns (n=30) of an alumina material system (densely sintered alumina) that had undergone three different pre-treatment modalities (water storage only; water storage and cyclic pre-loading; water storage, cyclic pre-loading, and thermocycling), (3) the fracture strength of all-ceramic FPDs (densely sintered alumina) supported by simulated teeth (n=12) or by dental implants (n=12).

Results: The success rate of the clinical alumina study was 90% after 5 years. Six (+/-1) years later (after a total of 11 +/-1 years), the success/survival rate was 65%. In the second clinical study, the success rates of the 2- and 3-year follow-ups were 100%. In the three in-vitro studies, the following results were found: (1a) the mean flexural strength of the specimens in the group that was exposed to saliva first after glazing was significantly higher (P < 0.001) than that of the specimens in the group that was exposed to saliva before glazing, (1b) the FPDs luted on shoulder preparations resisted higher loads than the FPDs luted on chamfer preparations (P = 0.051), 2) total fractures were more frequent in the alumina than in the zirconia group (P < 0.001), 3) FPDs loaded on implants resisted higher loads (mean = 604 N, SD=184 N ) than FPDs loaded on abutment teeth (mean= 378 N, SD=152 N, P = 0.003).

Conclusions: This thesis justifies the use of shorter alumina- (< or = three-unit) and zirconia-based (< or = five-unit) FPDs as the clinical results are acceptable. The clinical performance of alumina is, however, not as good as that of comparable high-gold alloy based porcelain-fused-to-metal FPDs concerning fracture resistance. Within the limitations of the in-vitro studies: Saliva exposure of porcelain before glaze firing should be avoided to optimize the strength of the porcelain. Shoulder preparations can be beneficial for the strength of all-ceramic FPDs compared to chamfer preparations, as can support by dental implants compared to abutment teeth. The fracture mode of alumina crowns (total fractures) differs from that of zirconia crowns (veneer fractures), suggesting that the zirconia core is stronger than the alumina core.

全瓷固定局部义齿。氧化铝和二氧化锆基陶瓷体系的研究。
背景:近年来,随着精细、更坚韧、更强的陶瓷芯材料的发展,基于氧化物陶瓷的新型、强全陶瓷体系得到了更广泛的应用。体外研究结果表明,氧化物陶瓷在短全陶瓷固定局部义齿(fpd)中的应用是积极的,但需要临床研究和额外的体外研究来证实这种方法的可行性。目的:本论文的一个目的是研究氧化铝基和氧化锆基材料系统是否适合用于较短(<或= 5个单元)的fpd,并评估临床结果。另外的目的是研究如何通过改变试入程序、基牙的颈椎形状和FPD(基牙或牙种植体)的支持来实现全陶瓷FPD的最佳断裂强度。最终目的是比较氧化锆材料系统的强度与氧化铝等效的已知长期临床性能。材料和方法:进行了两项临床研究,分别研究了一种氧化铝基和一种氧化锆基材料系统。20例后路3单元fpd(玻璃浸润氧化铝)随访5年,20例3 - 5单元fpd (HIP氧化锆)随访2年。11 +/-1(玻璃浸润氧化铝)和3年(氧化锆)后进行长期随访。在三个体外研究中,研究了以下变量:(1a)釉面烧制前(n=20)和釉面烧制后(n=20)首次接触唾液的瓷试件的抗折强度,(1b)三单元全陶瓷FPDs(玻璃浸润氧化铝)的断裂强度,分别由颈肩预备剂(n=9)和颈倒角预备剂(n=9)支撑,(2)由氧化锆材料体系(致密烧结氧化锆)制成的冠(n=30)和由氧化铝材料体系(致密烧结氧化铝)制成的冠(n=30)经过三种不同的预处理方式(仅蓄水;蓄水和循环预压;(3)由模拟牙齿(n=12)或种植牙(n=12)支撑的全陶瓷FPDs(致密烧结氧化铝)的断裂强度。结果:5年后临床氧化铝研究成功率为90%。6年(+/-1)年后(共11年+/-1),成功率/存活率为65%。在第二次临床研究中,2年和3年随访成功率均为100%。在这三项体外研究中,发现了以下结果:(1a)上釉后先接触唾液组的平均抗弯强度显著高于上釉前接触唾液组(P < 0.001); (1b)肩部制备的FPDs比倒角制备的FPDs抵抗更高的载荷(P = 0.051);(2)氧化铝组的总断裂比氧化锆组的更频繁(P < 0.001);3)种植体负载的fpd承受的载荷(平均604 N, SD=184 N)高于基牙负载的fpd(平均378 N, SD=152 N, P = 0.003)。结论:本论文证明使用较短的氧化铝基(<或= 3个单位)和氧化锆基(<或= 5个单位)fpd的临床结果是可以接受的。然而,在抗断裂性能方面,氧化铝的临床表现不如类似的高金合金基瓷熔合金属fpd。在体外研究的限制范围内:在釉烧前应避免唾液接触瓷器,以优化瓷器的强度。与倒角准备相比,肩部准备对全陶瓷fpd的强度有益,与基牙相比,牙种植体可以支持全陶瓷fpd。氧化铝冠的断裂模式(全断裂)与氧化锆冠的断裂模式(贴面断裂)不同,表明氧化锆核心比氧化铝核心更强。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书