A prospective multicentre registry of the procedural and long-term clinical and angiographic results of stent implantation using a Dylyn coated coronary stent system.
Robert Riezebos, Eelko Ronner, Ferdinand Kiemeneij, Gert-Jan Laarman
{"title":"A prospective multicentre registry of the procedural and long-term clinical and angiographic results of stent implantation using a Dylyn coated coronary stent system.","authors":"Robert Riezebos, Eelko Ronner, Ferdinand Kiemeneij, Gert-Jan Laarman","doi":"10.1080/14628840310030450","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>A prospective registry was performed to evaluate the safety and efficacy of a Dylyn coated coronary stent.</p><p><strong>Background: </strong>Diamond-like nanocomposite (Dylyn) stent coating is thought to be biocompatible, resulting in decreased thrombogenicity and decreased neointimal hyperplasia.</p><p><strong>Methods: </strong>In a multicentre, open, prospective, clinical and angiographical registry, the Dylyn-coated stent system was evaluated in patients requiring percutaneous coronary intervention. The primary procedural and angiographical endpoint of the study was the sustained success of stent-implantation using a follow-up catheterisation at six months. The primary clinical endpoint of the study was the composite incidence of death, non-fatal myocardial infarction and revascularisation at six months after stent implantation.</p><p><strong>Results: </strong>127 Dylyn coated coronary stents were implanted in 121 patients. Procedural success was obtained in 100% of the cases. No episodes of acute stent thrombosis occurred. The number of patients within stent restenosis at six months was 29 (24%). The primary procedural, angiographical endpoint was achieved in 91 (70%) patients. The clinical results at six-month follow-up were favourable with a MACE-rate of 7.4%.</p><p><strong>Conclusions: </strong>A Dylyn coated coronary stent system is well tolerated and has excellent short-term results. The amount of angiographic restenosis at 6 months, however, is considerable, but comparable to other non-drug-eluting stent systems.</p>","PeriodicalId":83747,"journal":{"name":"International journal of cardiovascular interventions","volume":"6 3-4","pages":"137-41"},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/14628840310030450","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of cardiovascular interventions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14628840310030450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Objectives: A prospective registry was performed to evaluate the safety and efficacy of a Dylyn coated coronary stent.
Background: Diamond-like nanocomposite (Dylyn) stent coating is thought to be biocompatible, resulting in decreased thrombogenicity and decreased neointimal hyperplasia.
Methods: In a multicentre, open, prospective, clinical and angiographical registry, the Dylyn-coated stent system was evaluated in patients requiring percutaneous coronary intervention. The primary procedural and angiographical endpoint of the study was the sustained success of stent-implantation using a follow-up catheterisation at six months. The primary clinical endpoint of the study was the composite incidence of death, non-fatal myocardial infarction and revascularisation at six months after stent implantation.
Results: 127 Dylyn coated coronary stents were implanted in 121 patients. Procedural success was obtained in 100% of the cases. No episodes of acute stent thrombosis occurred. The number of patients within stent restenosis at six months was 29 (24%). The primary procedural, angiographical endpoint was achieved in 91 (70%) patients. The clinical results at six-month follow-up were favourable with a MACE-rate of 7.4%.
Conclusions: A Dylyn coated coronary stent system is well tolerated and has excellent short-term results. The amount of angiographic restenosis at 6 months, however, is considerable, but comparable to other non-drug-eluting stent systems.