Initial experience using the NuMED Cheatham Platinum (CP) stent for interventional treatment of coarctation of the aorta in children and adolescents.

N A Haas, M A G Lewin, W Knirsch, R Nossal, V Ocker, F Uhlemann
{"title":"Initial experience using the NuMED Cheatham Platinum (CP) stent for interventional treatment of coarctation of the aorta in children and adolescents.","authors":"N A Haas,&nbsp;M A G Lewin,&nbsp;W Knirsch,&nbsp;R Nossal,&nbsp;V Ocker,&nbsp;F Uhlemann","doi":"10.1007/s00392-005-0180-y","DOIUrl":null,"url":null,"abstract":"<p><p>We report the immediate results in a group of selected patients with native or recurrent coarctation of the aorta who underwent endovascular stent implantation using the newly designed Cheatham-Platinum (CP)-stent. The balloon-expandable stents were implanted in 6 patients (mean age 12.7 years) with coarctation of the aorta (5 native, 1 recurrent). The maximal systolic peak pressure gradient was decreased from 49 to 3 mmHg (p <0.001). There was a 350% increase in the mean diameter at the original coarctation site (3.8 to 13.8 mm, p <0.01). Although the maximal diameter varied from 8 to 18 mm, there was only a minor reduction in the length of the CP-stents used (max. 11%). The dilatation was successful in all patients and there were no complications during balloon dilatation or stent implantation. All patients were hypertensive prior to stent implantation, with three of them requiring antihypertensive drug therapy. In 2 patients only a moderate dilatation diameter was chosen initially due to the extremely small coarctation site (1 mm) and repeat dilatation after 12 months was performed in order to obtain a maximal aortic diameter. At a mean of 18 months of follow-up, 5 of 6 patients are normotensive. There is no recurrence of coarctation, aortic dissection or aneurysm formation and no stent displacement. These findings suggest that the implantation of CP-stents for coarctation of the aortamay cover a wide spectrum of aortic diameters and consequently hereby offer an effective alternative approach to surgery or ballon dilatation alone even in infancy and childhood. The potential for redilatation of CP-stents in a wide range of diameters without significant shortening adds to the benefit of this device in growing children.</p>","PeriodicalId":23757,"journal":{"name":"Zeitschrift fur Kardiologie","volume":"94 2","pages":"113-20"},"PeriodicalIF":0.0000,"publicationDate":"2005-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s00392-005-0180-y","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur Kardiologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00392-005-0180-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

We report the immediate results in a group of selected patients with native or recurrent coarctation of the aorta who underwent endovascular stent implantation using the newly designed Cheatham-Platinum (CP)-stent. The balloon-expandable stents were implanted in 6 patients (mean age 12.7 years) with coarctation of the aorta (5 native, 1 recurrent). The maximal systolic peak pressure gradient was decreased from 49 to 3 mmHg (p <0.001). There was a 350% increase in the mean diameter at the original coarctation site (3.8 to 13.8 mm, p <0.01). Although the maximal diameter varied from 8 to 18 mm, there was only a minor reduction in the length of the CP-stents used (max. 11%). The dilatation was successful in all patients and there were no complications during balloon dilatation or stent implantation. All patients were hypertensive prior to stent implantation, with three of them requiring antihypertensive drug therapy. In 2 patients only a moderate dilatation diameter was chosen initially due to the extremely small coarctation site (1 mm) and repeat dilatation after 12 months was performed in order to obtain a maximal aortic diameter. At a mean of 18 months of follow-up, 5 of 6 patients are normotensive. There is no recurrence of coarctation, aortic dissection or aneurysm formation and no stent displacement. These findings suggest that the implantation of CP-stents for coarctation of the aortamay cover a wide spectrum of aortic diameters and consequently hereby offer an effective alternative approach to surgery or ballon dilatation alone even in infancy and childhood. The potential for redilatation of CP-stents in a wide range of diameters without significant shortening adds to the benefit of this device in growing children.

使用NuMED Cheatham白金(CP)支架介入治疗儿童和青少年主动脉缩窄的初步经验。
我们报告了一组选择的原发性或复发性主动脉缩窄的患者使用新设计的Cheatham-Platinum (CP)支架进行血管内支架植入术的直接结果。6例(平均年龄12.7岁)主动脉缩窄患者(5例为先天性,1例为复发性)植入球囊扩张支架。最大收缩期峰值压力梯度从49 mmHg (p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信