Magnetocardiography of animals in magnetically shielded environment with active compensation.

H E Horng, S H Liao, S J Hsu, H C Yang, J Y Wu, C C Chen, C H Wu, C C Wu
{"title":"Magnetocardiography of animals in magnetically shielded environment with active compensation.","authors":"H E Horng,&nbsp;S H Liao,&nbsp;S J Hsu,&nbsp;H C Yang,&nbsp;J Y Wu,&nbsp;C C Chen,&nbsp;C H Wu,&nbsp;C C Wu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A high-Tc 1st-order electronic superconducting quantum interference device (SQUID) gradiometer system is constructed to study the magnetocardiogram (MCG) of rabbits in a moderately magnetically shielded environment with active compensation. In the noisy hospital environment, the noise cannot be completely reduced with the 1st-order gradiometer, therefore, a reference SQUID with active compensation was used to further reduce the noise level leaking into the room. The MCG system was equipped with a x-y translation bed. We used a low-pass filter with the cut off frequency at 44 Hz, a high-pass filter with the cut off frequency at 0.1 Hz and the 60 Hz notch filter to reduce the power line interference. The noise level of the 1st order gradiometer MCG system in this moderately magnetically shielded room was about 1 pT/square root of Hz1/2 at 1 Hz. The MCG of a normal rabbits was measured with this system and a MCG contour map and a current density distribution was constructed.</p>","PeriodicalId":83814,"journal":{"name":"Neurology & clinical neurophysiology : NCN","volume":"2004 ","pages":"84"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurology & clinical neurophysiology : NCN","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A high-Tc 1st-order electronic superconducting quantum interference device (SQUID) gradiometer system is constructed to study the magnetocardiogram (MCG) of rabbits in a moderately magnetically shielded environment with active compensation. In the noisy hospital environment, the noise cannot be completely reduced with the 1st-order gradiometer, therefore, a reference SQUID with active compensation was used to further reduce the noise level leaking into the room. The MCG system was equipped with a x-y translation bed. We used a low-pass filter with the cut off frequency at 44 Hz, a high-pass filter with the cut off frequency at 0.1 Hz and the 60 Hz notch filter to reduce the power line interference. The noise level of the 1st order gradiometer MCG system in this moderately magnetically shielded room was about 1 pT/square root of Hz1/2 at 1 Hz. The MCG of a normal rabbits was measured with this system and a MCG contour map and a current density distribution was constructed.

主动补偿磁屏蔽环境下动物的心脏磁图。
构建了一种高tc一阶电子超导量子干涉器件(SQUID)梯度测量系统,用于研究兔在适度磁屏蔽环境下的主动补偿磁心图(MCG)。在嘈杂的医院环境中,一阶梯度仪无法完全降噪,因此,采用具有主动补偿的参考SQUID进一步降低泄漏到室内的噪声水平。MCG系统配备了一个x-y平移床。我们使用截止频率为44 Hz的低通滤波器,截止频率为0.1 Hz的高通滤波器和60 Hz陷波滤波器来减少电源线干扰。在中等磁屏蔽室内,一阶梯度仪MCG系统在1hz时的噪声水平约为1 pT/ Hz1/2的平方根。用该系统测量了正常家兔的MCG,绘制了MCG等高线图和电流密度分布图。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信