Ventricular unipolar potential in radiofrequency catheter ablation of idiopathic non-reentrant ventricular outflow tachycardia.

Yohkoh Soejima, Kazutaka Aonuma, Yoshito Iesaka, Mitsuaki Isobe
{"title":"Ventricular unipolar potential in radiofrequency catheter ablation of idiopathic non-reentrant ventricular outflow tachycardia.","authors":"Yohkoh Soejima,&nbsp;Kazutaka Aonuma,&nbsp;Yoshito Iesaka,&nbsp;Mitsuaki Isobe","doi":"10.1536/jhj.45.749","DOIUrl":null,"url":null,"abstract":"<p><p>We conducted this study to verify the efficacy of ventricular unipolar potential (V-uni) for ablation of idiopathic non-reentrant ventricular tachycardia (idio-VT). The morphology of V-uni at the successful and unsuccessful sites was analyzed in 27 patients with idio-VT [20 with right ventricular outflow tachycardia (RVOVT) and 7 with left ventricular outflow tachycardia (LVOVT)]. The usefulness of V-uni was compared with a pacemapping method and the V-QRS interval. The incidence of QS-pattern V-uni at the successful and best unsuccessful sites were 100 versus 25% (P = 0.000005) in RVOVT and 86 versus 29% (P = 0.10) in LVOVT. The pacemapping scores at the successful and best unsuccessful sites were 11.5/12 versus 11.2/12; NS in RVOVT, and 11.2/12 versus 11.1/12; NS in LVOVT. The mean V-QRS interval at the successful and the best unsuccessful sites were 22.5 +/- 3.8 versus 21.6 +/- 3.4 msec; NS in RVOVT, 15.1 +/- 3.2 versus 12.5 +/- 3.3 msec; NS in LVOVT. The sensitivity (sen) and specificity (spe) of QS-pattern V-uni to determine the optimum target sites were 1.0 and 0.89 in RVOVT and 0.86 and 0.83 in LVOVT, respectively. In the ablation of idio-VT, QS-pattern V-uni is simply and visually identifiable, is very useful, and should be given a high priority when determining the optimum target site.</p>","PeriodicalId":14717,"journal":{"name":"Japanese heart journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2004-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese heart journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1536/jhj.45.749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

We conducted this study to verify the efficacy of ventricular unipolar potential (V-uni) for ablation of idiopathic non-reentrant ventricular tachycardia (idio-VT). The morphology of V-uni at the successful and unsuccessful sites was analyzed in 27 patients with idio-VT [20 with right ventricular outflow tachycardia (RVOVT) and 7 with left ventricular outflow tachycardia (LVOVT)]. The usefulness of V-uni was compared with a pacemapping method and the V-QRS interval. The incidence of QS-pattern V-uni at the successful and best unsuccessful sites were 100 versus 25% (P = 0.000005) in RVOVT and 86 versus 29% (P = 0.10) in LVOVT. The pacemapping scores at the successful and best unsuccessful sites were 11.5/12 versus 11.2/12; NS in RVOVT, and 11.2/12 versus 11.1/12; NS in LVOVT. The mean V-QRS interval at the successful and the best unsuccessful sites were 22.5 +/- 3.8 versus 21.6 +/- 3.4 msec; NS in RVOVT, 15.1 +/- 3.2 versus 12.5 +/- 3.3 msec; NS in LVOVT. The sensitivity (sen) and specificity (spe) of QS-pattern V-uni to determine the optimum target sites were 1.0 and 0.89 in RVOVT and 0.86 and 0.83 in LVOVT, respectively. In the ablation of idio-VT, QS-pattern V-uni is simply and visually identifiable, is very useful, and should be given a high priority when determining the optimum target site.

射频导管消融治疗特发性非再入性室性流出性心动过速的心室单极电位。
我们进行了这项研究,以验证心室单极电位(V-uni)消融特发性非再入性室性心动过速(idio-VT)的有效性。分析27例idio-VT患者(20例右心室流出性心动过速(RVOVT), 7例左心室流出性心动过速(LVOVT))成功部位和不成功部位的V-uni形态。比较了V-uni与心脏搏动法和V-QRS间期的有效性。在RVOVT和LVOVT中,成功部位和最佳不成功部位的qs型V-uni发生率分别为100和25% (P = 0.000005)和86和29% (P = 0.10)。成功位点和最佳不成功位点的心脏搏动评分分别为11.5/12和11.2/12;RVOVT的NS和11.2/12比11.1/12;在LVOVT。成功位点和最佳不成功位点的平均V-QRS间隔分别为22.5 +/- 3.8和21.6 +/- 3.4 msec;RVOVT的NS分别为15.1 +/- 3.2和12.5 +/- 3.3 msec;在LVOVT。qs型V-uni对RVOVT和LVOVT最佳靶位的敏感性(sen)和特异性(spe)分别为1.0和0.89和0.86和0.83。在idio-VT消融中,qs型V-uni简单且可视觉识别,非常有用,在确定最佳靶位时应优先考虑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信