Percutaneous transcatheter repositioning of displaced permanent pacemaker atrial lead with a simple system.

Hurkan Kursaklioglu, Cem Barcin, Atila Iyisoy, Sedat Kose, Ersoy Isik
{"title":"Percutaneous transcatheter repositioning of displaced permanent pacemaker atrial lead with a simple system.","authors":"Hurkan Kursaklioglu,&nbsp;Cem Barcin,&nbsp;Atila Iyisoy,&nbsp;Sedat Kose,&nbsp;Ersoy Isik","doi":"10.1080/14628840410030388","DOIUrl":null,"url":null,"abstract":"<p><p>A 48-year-old man who was implanted with a DDD-R pacemaker because of sick sinus syndrome eight days ago presented to our institute with a syncopal attack. Fluoroscopy showed a dislodged active fixation atrial pacemaker lead. With a snare system simply improvised from a 0.014 inch guidewire and a NIH catheter, the lead was repositioned via percutaneous transfemoral approach. The procedure was easy and completed without any complication. Follow-up controls after two weeks and three months showed stability of the lead position with normal pacing and sensing functions.</p>","PeriodicalId":83747,"journal":{"name":"International journal of cardiovascular interventions","volume":"6 2","pages":"88-90"},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/14628840410030388","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of cardiovascular interventions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14628840410030388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A 48-year-old man who was implanted with a DDD-R pacemaker because of sick sinus syndrome eight days ago presented to our institute with a syncopal attack. Fluoroscopy showed a dislodged active fixation atrial pacemaker lead. With a snare system simply improvised from a 0.014 inch guidewire and a NIH catheter, the lead was repositioned via percutaneous transfemoral approach. The procedure was easy and completed without any complication. Follow-up controls after two weeks and three months showed stability of the lead position with normal pacing and sensing functions.

用简易系统经皮置换术重新定位永久性起搏器心房导联。
一名48岁男子,8天前因窦性疾病综合征植入了DDD-R起搏器,因晕厥发作来到我所。透视显示主动固定心房起搏器导线移位。使用0.014英寸导丝和NIH导管简易的诱骗系统,通过经皮经股入路重新定位导线。手术过程简单,没有任何并发症。随访2周和3个月后的对照组显示导联位置稳定,起搏和传感功能正常。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书