{"title":"Health care workers: risk factors for nonlatex and latex gloves during surgery.","authors":"Denise M Korniewicz,&nbsp;Laurel Garzon,&nbsp;Stacey Plitcha","doi":"10.1202/542.1","DOIUrl":null,"url":null,"abstract":"<p><p>This study examined glove failure and related factors in both nonlatex and latex surgical gloves after routine use. A federally funded research study was conducted to collect surgical gloves from those directly involved in surgical procedures. All gloves were examined in the laboratory for both visual defects and barrier integrity. A total of 11,118 usable surgical gloves were examined. The overall defect rate was 7.8%; nonlatex gloves were significantly more likely to fail (8.4%) than latex gloves (6.9%). The majority of defects in the latex gloves (90%) and nonlatex gloves (70%) were not detected by visual examination. Separate logistic regression models examined predictors of defects for the gloves. The only factor that increased the odds of a defect for a latex glove was duration of use over 6 hours. Factors increasing the odds of a defect in nonlatex gloves included gloves worn by a scrub person and gloves used in certain surgical services. Scrub persons had a higher defect rate despite wearing their gloves for a significantly shorter time than other health care workers. Latex and nonlatex gloves fail under different conditions. Latex gloves fail primarily due to length of use, whereas nonlatex gloves are more sensitive to conditions of us (e.g., type of health care worker and type of surgery). Providers can help guard against glove defects by double gloving and by changing gloves often, especially when using nonlatex gloves in higher-risk surgeries.</p>","PeriodicalId":83618,"journal":{"name":"AIHA journal : a journal for the science of occupational and environmental health and safety","volume":"64 6","pages":"851-5"},"PeriodicalIF":0.0000,"publicationDate":"2003-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIHA journal : a journal for the science of occupational and environmental health and safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1202/542.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study examined glove failure and related factors in both nonlatex and latex surgical gloves after routine use. A federally funded research study was conducted to collect surgical gloves from those directly involved in surgical procedures. All gloves were examined in the laboratory for both visual defects and barrier integrity. A total of 11,118 usable surgical gloves were examined. The overall defect rate was 7.8%; nonlatex gloves were significantly more likely to fail (8.4%) than latex gloves (6.9%). The majority of defects in the latex gloves (90%) and nonlatex gloves (70%) were not detected by visual examination. Separate logistic regression models examined predictors of defects for the gloves. The only factor that increased the odds of a defect for a latex glove was duration of use over 6 hours. Factors increasing the odds of a defect in nonlatex gloves included gloves worn by a scrub person and gloves used in certain surgical services. Scrub persons had a higher defect rate despite wearing their gloves for a significantly shorter time than other health care workers. Latex and nonlatex gloves fail under different conditions. Latex gloves fail primarily due to length of use, whereas nonlatex gloves are more sensitive to conditions of us (e.g., type of health care worker and type of surgery). Providers can help guard against glove defects by double gloving and by changing gloves often, especially when using nonlatex gloves in higher-risk surgeries.

卫生保健工作者:手术中使用非乳胶和乳胶手套的危险因素。
本研究检查了常规使用后非乳胶和乳胶手术手套的手套失效及其相关因素。一项由联邦政府资助的研究旨在收集那些直接参与外科手术的人的手术手套。所有手套都在实验室进行了视觉缺陷和屏障完整性检查。共检查了11,118只可用的外科手套。总体缺陷率为7.8%;非乳胶手套(8.4%)比乳胶手套(6.9%)更容易失效。大多数乳胶手套(90%)和非乳胶手套(70%)的缺陷不能通过目测检测出来。单独的逻辑回归模型检查了手套缺陷的预测因子。增加乳胶手套缺陷几率的唯一因素是使用时间超过6小时。增加非乳胶手套缺陷几率的因素包括擦洗人员戴的手套和某些外科手术中使用的手套。与其他卫生保健工作者相比,清洁人员尽管戴手套的时间明显较短,但其不良率较高。乳胶和非乳胶手套在不同的条件下失效。乳胶手套的失效主要是由于使用时间长,而非乳胶手套对我们的条件更敏感(例如,卫生保健工作者的类型和手术的类型)。医护人员可以通过双套手套和经常更换手套来防止手套缺陷,特别是在高风险手术中使用非乳胶手套时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信