32P liquid sources—comparison of the effectiveness of postangioplasty versus poststenting intravascular brachytherapy in hypercholesterolemic rabbits

Piotr Walichiewicz , Barbara Petelenz , Krzysztof Wilczek , Wojciech Jacheć , Jerzy Jochem , Andrzej Tomasik , Dariusz Lange , Jan Wodniecki
{"title":"32P liquid sources—comparison of the effectiveness of postangioplasty versus poststenting intravascular brachytherapy in hypercholesterolemic rabbits","authors":"Piotr Walichiewicz ,&nbsp;Barbara Petelenz ,&nbsp;Krzysztof Wilczek ,&nbsp;Wojciech Jacheć ,&nbsp;Jerzy Jochem ,&nbsp;Andrzej Tomasik ,&nbsp;Dariusz Lange ,&nbsp;Jan Wodniecki","doi":"10.1016/S1522-1865(03)00145-8","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>Endovascular application of ionizing radiation is a promising but still not sufficiently studied means of restenosis prevention. To test the effects of radiation on restenosis, and especially their dependence on whether the angioplasty was followed by stent implantation or not, we performed an in-stent versus no-stent intravascular brachytherapy study in an animal model. Balloon-based, continuous and self-centering, liquid <sup>32</sup>P sources seemed the most convenient for the purpose.</p></div><div><h3>Method</h3><p>The radial dose distribution around angioplasty balloons filled with solutions of Na<sub>2</sub>H<sup>32</sup>PO<sub>4</sub> was calibrated by thermoluminescence dosimetry, both in the absence and presence of stents. The animal experiments were performed on rabbits with induced hypercholesterolemia. The balloons containing <sup>32</sup>P were introduced into iliac artery immediately after stent implantation or after angioplasty alone. Radiation effects were evaluated postmortem by comparing thickness of various components of the artery wall.</p></div><div><h3>Results</h3><p>In the presence of titanium stents (TTS), irradiation with 16 Gy dose at 1.0 mm from the balloon surface was no less effective in reducing hypertrophy in every active layer of the artery wall than without a stent.</p></div><div><h3>Conclusion</h3><p>In the animal model, IVBT basing on P<sup>32</sup> liquid sources was no less effective in the stented arteries than in the nonstented ones.</p></div>","PeriodicalId":80261,"journal":{"name":"Cardiovascular radiation medicine","volume":"4 2","pages":"Pages 64-68"},"PeriodicalIF":0.0000,"publicationDate":"2003-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1522-1865(03)00145-8","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular radiation medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1522186503001458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Purpose

Endovascular application of ionizing radiation is a promising but still not sufficiently studied means of restenosis prevention. To test the effects of radiation on restenosis, and especially their dependence on whether the angioplasty was followed by stent implantation or not, we performed an in-stent versus no-stent intravascular brachytherapy study in an animal model. Balloon-based, continuous and self-centering, liquid 32P sources seemed the most convenient for the purpose.

Method

The radial dose distribution around angioplasty balloons filled with solutions of Na2H32PO4 was calibrated by thermoluminescence dosimetry, both in the absence and presence of stents. The animal experiments were performed on rabbits with induced hypercholesterolemia. The balloons containing 32P were introduced into iliac artery immediately after stent implantation or after angioplasty alone. Radiation effects were evaluated postmortem by comparing thickness of various components of the artery wall.

Results

In the presence of titanium stents (TTS), irradiation with 16 Gy dose at 1.0 mm from the balloon surface was no less effective in reducing hypertrophy in every active layer of the artery wall than without a stent.

Conclusion

In the animal model, IVBT basing on P32 liquid sources was no less effective in the stented arteries than in the nonstented ones.

32P液体源-血管成形术后与支架置入后血管内近距离治疗高胆固醇血症家兔的疗效比较
目的在血管内应用电离辐射是一种很有前途但尚未得到充分研究的预防再狭窄的方法。为了测试放射对再狭窄的影响,特别是它们是否依赖于血管成形术后是否植入支架,我们在动物模型中进行了支架内和非支架血管内近距离放疗研究。基于气球的、连续的、自定心的液体32P源似乎是最方便的。方法采用热释光剂量法测定血管成形术球囊内填充Na2H32PO4溶液的放射剂量分布。动物实验采用诱导性高胆固醇血症家兔进行。将含有32P的球囊在支架植入后或单独血管成形术后立即导入髂动脉。通过比较动脉壁各成分的厚度来评估死后的辐射效应。结果在有钛支架的情况下,距球囊表面1.0 mm的16 Gy剂量照射对动脉壁各活动层肥厚的减轻效果并不亚于没有支架的情况。结论在动物模型中,基于P32液体源的IVBT对支架动脉的治疗效果不低于未支架动脉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信