Transmyocardial laser revascularization: epicardial ECG detection provides efficient R-wave triggering during mobilization of the heart.

Thomas Wild, Nermin Serbecic, Sven Christoph Beutelspacher, Meinhard Ploner, Zeno Deckert, Rainald Seitelberger
{"title":"Transmyocardial laser revascularization: epicardial ECG detection provides efficient R-wave triggering during mobilization of the heart.","authors":"Thomas Wild,&nbsp;Nermin Serbecic,&nbsp;Sven Christoph Beutelspacher,&nbsp;Meinhard Ploner,&nbsp;Zeno Deckert,&nbsp;Rainald Seitelberger","doi":"10.1089/104454703321895590","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In order to achieve an accurate intraoperative ECG detection, a new technique in detecting the trigger-signal was developed. In contrast to the traditional three-lead ECG-configuration, the left leg electrode was connected to a transient epicardial pacemaker electrode on the left-ventricular surface.</p><p><strong>Background data: </strong>The Holmium:YAG-Laser for Transmyocardial Laser Revascularization (TMLR) is R-wave-triggered, providing the release of energy only during the refractory period of the heart cycle. However, an exact ECG-triggering during mobilization of the apex and/or posterior wall is difficult to achieve by using conventional ECG-configuration, therefore increasing the risk for mistriggering and induction of arrhythmias during TMLR.</p><p><strong>Materials and methods: </strong>Two groups of patients, all undergoing stand alone TMLR-procedures via left minithoracotomy, were compared. Ten patients were operated with the conventional ECG configuration (group 1) and ten patients with the modified epicardial ECG configuration (group 2).</p><p><strong>Results: </strong>In patients of group 1, as a result of a loss of the trigger signal or due to the triggering of artifacts, the incidence of correctly triggered QRS-complexes was 56% of all documented QRS-complexes. In contrast, an excellent triggering was observed in 98% (p < 0.001) in group 2, resulting in a reduction of laser operative time by 35% (p < 0.001) and a decrease in the incidence of intraoperative ventricular fibrillation (0 vs. 3).</p><p><strong>Conclusion: </strong>In conclusion, this new ECG configuration is a simple but effective method in achieving an excellent ECG signal during all stages of TMLR. As a consequence, a reduction in operative time and incidence of ventricular fibrillation can be achieved.</p>","PeriodicalId":79503,"journal":{"name":"Journal of clinical laser medicine & surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/104454703321895590","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical laser medicine & surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/104454703321895590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Objective: In order to achieve an accurate intraoperative ECG detection, a new technique in detecting the trigger-signal was developed. In contrast to the traditional three-lead ECG-configuration, the left leg electrode was connected to a transient epicardial pacemaker electrode on the left-ventricular surface.

Background data: The Holmium:YAG-Laser for Transmyocardial Laser Revascularization (TMLR) is R-wave-triggered, providing the release of energy only during the refractory period of the heart cycle. However, an exact ECG-triggering during mobilization of the apex and/or posterior wall is difficult to achieve by using conventional ECG-configuration, therefore increasing the risk for mistriggering and induction of arrhythmias during TMLR.

Materials and methods: Two groups of patients, all undergoing stand alone TMLR-procedures via left minithoracotomy, were compared. Ten patients were operated with the conventional ECG configuration (group 1) and ten patients with the modified epicardial ECG configuration (group 2).

Results: In patients of group 1, as a result of a loss of the trigger signal or due to the triggering of artifacts, the incidence of correctly triggered QRS-complexes was 56% of all documented QRS-complexes. In contrast, an excellent triggering was observed in 98% (p < 0.001) in group 2, resulting in a reduction of laser operative time by 35% (p < 0.001) and a decrease in the incidence of intraoperative ventricular fibrillation (0 vs. 3).

Conclusion: In conclusion, this new ECG configuration is a simple but effective method in achieving an excellent ECG signal during all stages of TMLR. As a consequence, a reduction in operative time and incidence of ventricular fibrillation can be achieved.

经心肌激光血运重建术:心外膜心电图检测在心脏活动期间提供有效的r波触发。
目的:为实现术中心电的准确检测,研究了一种新的心电触发信号检测技术。与传统的三导联心电图配置不同,左腿电极连接到左心室表面的瞬态心外膜起搏器电极。背景资料:用于经心肌激光血运重建术(TMLR)的钬:yag激光器是r波触发的,仅在心脏周期的不应期提供能量释放。然而,在心尖和/或后壁活动期间,使用传统的心电图配置很难实现精确的心电图触发,因此增加了TMLR期间误触发和诱发心律失常的风险。材料和方法:比较两组患者均通过左侧小开胸行独立tmlr手术。10例患者采用常规心电图配置(1组),10例患者采用改良心外膜心电图配置(2组)。结果:在1组患者中,由于触发信号丢失或由于触发伪影,正确触发qrs复合物的发生率为所有记录的qrs复合物的56%。相比之下,第二组有98% (p < 0.001)的触发率良好,导致激光手术时间减少35% (p < 0.001),术中心室颤动发生率降低(0比3)。结论:总之,这种新的心电图配置是一种简单而有效的方法,可以在TMLR的所有阶段获得良好的心电图信号。因此,可以减少手术时间和心室颤动的发生率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信