Development of a portable bruxism monitoring and analysis device equipped with a microcomputer and its practical application.

Ryuji Sakagami, Takeshi Horii, Shuichi Ino, Kazunari Matoba, Hiroshi Kato, Masamitsu Kawanami
{"title":"Development of a portable bruxism monitoring and analysis device equipped with a microcomputer and its practical application.","authors":"Ryuji Sakagami,&nbsp;Takeshi Horii,&nbsp;Shuichi Ino,&nbsp;Kazunari Matoba,&nbsp;Hiroshi Kato,&nbsp;Masamitsu Kawanami","doi":"10.1163/156855701321138941","DOIUrl":null,"url":null,"abstract":"<p><p>The purposes of this study were to develop and verify the a portable nocturnal bruxism monitoring and analysis device equipped with a microcomputer, and to clinically apply the device to know the actual conditions of bruxism patients. EEPROM was installed in the device for the data recording, and after the data collection, the recorded data was entered into a personal computer via serial port. After confirming the accuracy of the device, a total of 30 subjects were enrolled in this study to monitor their bruxism activities for 3 nights. Bruxism self-aware group consisted of 14 subjects, 7 males and 7 females, and unaware group consisted of 16 patients, 8 males and 8 females. Most of the subjects reported that the new device was easy to handle. The average bruxism time per hour and the average bruxism lasting time were 223.8 +/- 112.0 and 3.9 +/- 2.9 s in the self-aware group, and 49.3 +/- 38.3 and 0.8 +/- 0.7 s in the unaware group, respectively. The bruxism self-aware group showed statistically longer average bruxism time per hour and the average bruxism lasting time. It was confirmed that the new bruxism monitoring and analysis device is practical for clinical application to monitor and analyze the electromyographic activities.</p>","PeriodicalId":77139,"journal":{"name":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","volume":"11 4","pages":"295-306"},"PeriodicalIF":0.0000,"publicationDate":"2002-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1163/156855701321138941","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1163/156855701321138941","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The purposes of this study were to develop and verify the a portable nocturnal bruxism monitoring and analysis device equipped with a microcomputer, and to clinically apply the device to know the actual conditions of bruxism patients. EEPROM was installed in the device for the data recording, and after the data collection, the recorded data was entered into a personal computer via serial port. After confirming the accuracy of the device, a total of 30 subjects were enrolled in this study to monitor their bruxism activities for 3 nights. Bruxism self-aware group consisted of 14 subjects, 7 males and 7 females, and unaware group consisted of 16 patients, 8 males and 8 females. Most of the subjects reported that the new device was easy to handle. The average bruxism time per hour and the average bruxism lasting time were 223.8 +/- 112.0 and 3.9 +/- 2.9 s in the self-aware group, and 49.3 +/- 38.3 and 0.8 +/- 0.7 s in the unaware group, respectively. The bruxism self-aware group showed statistically longer average bruxism time per hour and the average bruxism lasting time. It was confirmed that the new bruxism monitoring and analysis device is practical for clinical application to monitor and analyze the electromyographic activities.

一种便携式微机磨牙监测分析装置的研制及实际应用。
本研究的目的是研制并验证一种装有微型计算机的便携式夜间磨牙监测分析装置,并应用于临床了解磨牙患者的实际情况。设备内安装EEPROM进行数据记录,数据采集完成后,通过串口将记录的数据输入个人计算机。在确认该装置的准确性后,本研究共招募了30名受试者,对他们的磨牙活动进行了3个晚上的监测。磨牙自我意识组14例,男7例,女7例;磨牙自我意识组16例,男8例,女8例。大多数受试者报告说,这种新设备很容易操作。自我意识组平均每小时磨牙时间为223.8 +/- 112.0 s,平均持续磨牙时间为3.9 +/- 2.9 s;无意识组平均每小时磨牙时间为49.3 +/- 38.3 s,平均持续磨牙时间为0.8 +/- 0.7 s。磨牙自我意识组每小时平均磨牙时间和平均磨牙持续时间更长。结果表明,这种新型磨牙监测分析装置可用于临床监测和分析磨牙患者的肌电活动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信