{"title":"[Determination of roxithromycin in serum by high-performance liquid chromatography with ultraviolet detection].","authors":"Y Qin, Y Zou, M Liang, Y Huang, Q Yu, P Feng","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To make better the RP-HPLC method for the determination of roxithromycin(RM) in human serum.</p><p><strong>Methods: </strong>RM and clarithromycin (internal standard) were extracted from alkalinized serum sample (500 microliters) with methylene chloride. After evaporation of the organic layer, the residue was dissolved in 100 microliters of acetonitrile-ammonium phosphate (1:1, pH 6.0) and washed with n-hexane, then 20 microliters was injected onto a column (5 microns, 15 cm x 4.6 mm) of Penomenex luna C18. The mobile phase was acetonitrile-0.05 mol/L phosphoric acid (39:19:42, adjusted to pH 7.2 with ammonia water) pumped at 1.2 ml/min through the column. The variable wavelength UV detector operated at 0.01 aufs and the wavelength was set at 210 nm.</p><p><strong>Results: </strong>The retention times for RM and clarithromycin were 4.4 min and 5.0 min, respectively. Standard curve was linear in the concentration range of 0.25 to 32 mg/L. The detection limit in serum was 0.06 mg/L; the average method recovery 97.4%; the inter-day RSD less than 3.0%.</p><p><strong>Conclusion: </strong>This method was found to be simple, rapid, sensitive and accurate for determination of RM in human serum.</p>","PeriodicalId":13173,"journal":{"name":"Hua xi yi ke da xue xue bao = Journal of West China University of Medical Sciences = Huaxi yike daxue xuebao","volume":"32 4","pages":"612-4"},"PeriodicalIF":0.0000,"publicationDate":"2001-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hua xi yi ke da xue xue bao = Journal of West China University of Medical Sciences = Huaxi yike daxue xuebao","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To make better the RP-HPLC method for the determination of roxithromycin(RM) in human serum.
Methods: RM and clarithromycin (internal standard) were extracted from alkalinized serum sample (500 microliters) with methylene chloride. After evaporation of the organic layer, the residue was dissolved in 100 microliters of acetonitrile-ammonium phosphate (1:1, pH 6.0) and washed with n-hexane, then 20 microliters was injected onto a column (5 microns, 15 cm x 4.6 mm) of Penomenex luna C18. The mobile phase was acetonitrile-0.05 mol/L phosphoric acid (39:19:42, adjusted to pH 7.2 with ammonia water) pumped at 1.2 ml/min through the column. The variable wavelength UV detector operated at 0.01 aufs and the wavelength was set at 210 nm.
Results: The retention times for RM and clarithromycin were 4.4 min and 5.0 min, respectively. Standard curve was linear in the concentration range of 0.25 to 32 mg/L. The detection limit in serum was 0.06 mg/L; the average method recovery 97.4%; the inter-day RSD less than 3.0%.
Conclusion: This method was found to be simple, rapid, sensitive and accurate for determination of RM in human serum.