Histological and scanning electron microscope examination of root canal after preparation with Er:YAG laser microprobe: a preliminary in vitro study.

Gavriel Kesler, Rivka Gal, Anat Kesler, Rumelia Koren
{"title":"Histological and scanning electron microscope examination of root canal after preparation with Er:YAG laser microprobe: a preliminary in vitro study.","authors":"Gavriel Kesler,&nbsp;Rivka Gal,&nbsp;Anat Kesler,&nbsp;Rumelia Koren","doi":"10.1089/10445470260420786","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Until now, there has been no study that demonstrates the effectiveness of Er:YAG laser microprobes to clean and shape the root canal without using any mechanical instrumentation.</p><p><strong>Materials and methods: </strong>The study was conducted on 28 single-rooted extracted central incisors teeth with straight roots. Fourteen were mechanically prepared and served as the control group, and 14 were treated by Er:YAG laser only. From every group, half of the teeth were examined histiolgically and half by SEM. The instrument tested was an Er:YAG laser with microprobes 200-400 micro in diameter and 20 mm in length, coupled onto special handpieces, attached to the delivery fiber of an OPUS 20 Er:YAG laser. The Er:YAG laser was applied with the following parameters: wavelength 2.94 microm; pulse duration 400 msec; repetition rate 10 Hz; energy per pulse 140 mJ for the 400 micro microprobe and 90 mJ for the 200-micro microprobe.</p><p><strong>Results: </strong>For the control group, histologically, large amounts of residual pulp tissue were found in the root canal cavity, and open tubules were seen in all the specimens; SEM examination showed very uniform root canal, from apical to cervical portion, high number of open tubules, and different levels of canal debridment. For the study group, histologically, no residual pulp tissue was found in the root canal cavity and open tubules were seen in all the specimens; SEM examination showed the root canal free of debris, removed smear layer, open dentinal tubules, and different levels of enlargement.</p><p><strong>Conclusion: </strong>Our results show that the Er:YAG laser special microprobes are effective in shaping, cleaning, and enlarging straight root canals faster and more efficiently then traditional methods.</p>","PeriodicalId":79503,"journal":{"name":"Journal of clinical laser medicine & surgery","volume":"20 5","pages":"269-77"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/10445470260420786","citationCount":"29","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical laser medicine & surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/10445470260420786","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

Abstract

Objective: Until now, there has been no study that demonstrates the effectiveness of Er:YAG laser microprobes to clean and shape the root canal without using any mechanical instrumentation.

Materials and methods: The study was conducted on 28 single-rooted extracted central incisors teeth with straight roots. Fourteen were mechanically prepared and served as the control group, and 14 were treated by Er:YAG laser only. From every group, half of the teeth were examined histiolgically and half by SEM. The instrument tested was an Er:YAG laser with microprobes 200-400 micro in diameter and 20 mm in length, coupled onto special handpieces, attached to the delivery fiber of an OPUS 20 Er:YAG laser. The Er:YAG laser was applied with the following parameters: wavelength 2.94 microm; pulse duration 400 msec; repetition rate 10 Hz; energy per pulse 140 mJ for the 400 micro microprobe and 90 mJ for the 200-micro microprobe.

Results: For the control group, histologically, large amounts of residual pulp tissue were found in the root canal cavity, and open tubules were seen in all the specimens; SEM examination showed very uniform root canal, from apical to cervical portion, high number of open tubules, and different levels of canal debridment. For the study group, histologically, no residual pulp tissue was found in the root canal cavity and open tubules were seen in all the specimens; SEM examination showed the root canal free of debris, removed smear layer, open dentinal tubules, and different levels of enlargement.

Conclusion: Our results show that the Er:YAG laser special microprobes are effective in shaping, cleaning, and enlarging straight root canals faster and more efficiently then traditional methods.

Er:YAG激光微探针制备根管后的组织学和扫描电镜观察:体外初步研究。
目的:到目前为止,还没有研究证明Er:YAG激光微探针在不使用任何机械器械的情况下清洁和塑造根管的有效性。材料与方法:选取28颗单根拔牙直根中切牙进行研究。机械制备14只作为对照组,单纯Er:YAG激光治疗14只。每组一半的牙齿进行组织学检查,一半进行扫描电镜检查。测试的仪器是一个Er:YAG激光器,直径200-400微米,长度20毫米的微探头,耦合到特殊的手持装置上,连接到OPUS 20 Er:YAG激光器的传输光纤上。Er:YAG激光器的波长为2.94微米;脉冲持续时间400毫秒;重复频率10hz;每脉冲能量为140 mJ的400微微探针和90 mJ的200微微探针。结果:对照组在组织学上根管腔内可见大量残留的牙髓组织,所有标本均可见开放的小管;扫描电镜显示根管非常均匀,从根尖到颈段,开放小管数量多,根管清创程度不同。研究组在组织学上,根管腔内未见残留髓质组织,所有标本均见开放小管;扫描电镜检查显示根管无杂物,涂片层去除,牙本质小管打开,不同程度增大。结论:Er:YAG激光专用探针在直根管整形、清洁和扩大方面比传统方法更快、更有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信