{"title":"Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults","authors":"S.A Ballantyne,&nbsp;G O'Neill,&nbsp;R Hamilton,&nbsp;A.S Hollman","doi":"10.1016/S0929-8266(02)00036-8","DOIUrl":null,"url":null,"abstract":"<div><p><em>Aim:</em> To quantify the observer variation in the sonographic measurement of optic nerve sheath diameter (ONSD) in normal adults. <em>Materials and methods:</em> Sixty-seven normal adult volunteers underwent ultrasound examination of each eye by three independent observers using a 7 MHz sector probe. Three measurements were made of each eye by each observer and a mean value calculated for each eye. Median and 5th–95th centile values for both intra- and inter-observer variation were calculated for the three observers. <em>Results:</em> The median intra-observer variation was ±0.1 mm, with 5th–95th centile values of ±0–0.4 mm. The median inter-observer variation was ±0.2–0.3 mm, with 5th–95th centile values of ±0–0.7 mm. Careful review of examination technique by the three observers after the first 17 examinations was shown to reduce both intra- and inter-observer variation. <em>Conclusion:</em> The sonographic measurement of ONSD is a readily learned, reproducible technique with low intra- and inter-observer variation. The average inter-observer variation (±0.2 mm) is comparable to the inherent variability of the ultrasound machine. The importance of standardisation of examination technique is stressed.</p></div>","PeriodicalId":79592,"journal":{"name":"European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology","volume":"15 3","pages":"Pages 145-149"},"PeriodicalIF":0.0000,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0929-8266(02)00036-8","citationCount":"208","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0929826602000368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 208

Abstract

Aim: To quantify the observer variation in the sonographic measurement of optic nerve sheath diameter (ONSD) in normal adults. Materials and methods: Sixty-seven normal adult volunteers underwent ultrasound examination of each eye by three independent observers using a 7 MHz sector probe. Three measurements were made of each eye by each observer and a mean value calculated for each eye. Median and 5th–95th centile values for both intra- and inter-observer variation were calculated for the three observers. Results: The median intra-observer variation was ±0.1 mm, with 5th–95th centile values of ±0–0.4 mm. The median inter-observer variation was ±0.2–0.3 mm, with 5th–95th centile values of ±0–0.7 mm. Careful review of examination technique by the three observers after the first 17 examinations was shown to reduce both intra- and inter-observer variation. Conclusion: The sonographic measurement of ONSD is a readily learned, reproducible technique with low intra- and inter-observer variation. The average inter-observer variation (±0.2 mm) is comparable to the inherent variability of the ultrasound machine. The importance of standardisation of examination technique is stressed.

正常成人视神经鞘直径超声测量的观察差异
目的:量化正常成人视神经鞘直径超声测量的观察者变化。材料和方法:67名正常成年志愿者由3名独立观察员使用7 MHz扇形探头对每只眼睛进行超声检查。每个观察者对每只眼睛进行三次测量,并计算每只眼睛的平均值。计算了三个观测者内部和观测者之间变异的中位数和第5 - 95百分位值。结果:观察者内变异中位数为±0.1 mm,第5 - 95百分位值为±0-0.4 mm。观察者间变异中位数为±0.2-0.3 mm,第5 - 95百分位值为±0-0.7 mm。在前17次检查后,三位观察员对检查技术进行了仔细的审查,这表明可以减少观察员内部和观察员之间的差异。结论:超声测量ONSD是一种易于学习、可重复的技术,具有较低的观察者内部和观察者之间的差异。观察者之间的平均变化(±0.2 mm)与超声机的固有变异性相当。强调了考试技术标准化的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信