{"title":"A comparison of the initial pain response following insertion of the Copper 7 and combined Multiload Copper 250-short IUDs.","authors":"N D Goldstuck","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The immediate postinsertion and 3 minute postinsertion pain response in nulliparous women undergoing insertion of either the Copper 7 (Cu 7) or the Multiload Copper 250-short (ML Cu 250-short) IUD has been studied. 35 women were fitted with a Cu 7 device and 23 with the ML Cu 250-short. The immediate postinsertion pain scores were significantly higher in the ML Cu 250-short group than in the Cu 7 group. There was no significant difference between the 3 minutes postinsertion scores for the 2 groups. The 3 minute pain scores were significantly lower than the immediate pain scores for each individual device group. Immediate postinsertion IUD pain may be related to the presenting diameter and insertional mechanism of the device. This pain is of short duration and after 3 minutes, the level of pain is independent of the type of device which has been inserted. The rapid diminution of pain at 3 minutes postinsertion indicates that the routine use of certain analgesic techniques, e.g., paracervical block before IUD insertion, is not justified. Pain following IUD insertion may provide a useful model for the study of various types of peripheral and centrally acting analgesics.</p>","PeriodicalId":84493,"journal":{"name":"Contraceptive delivery systems","volume":"2 4","pages":"295-301"},"PeriodicalIF":0.0000,"publicationDate":"1981-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contraceptive delivery systems","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The immediate postinsertion and 3 minute postinsertion pain response in nulliparous women undergoing insertion of either the Copper 7 (Cu 7) or the Multiload Copper 250-short (ML Cu 250-short) IUD has been studied. 35 women were fitted with a Cu 7 device and 23 with the ML Cu 250-short. The immediate postinsertion pain scores were significantly higher in the ML Cu 250-short group than in the Cu 7 group. There was no significant difference between the 3 minutes postinsertion scores for the 2 groups. The 3 minute pain scores were significantly lower than the immediate pain scores for each individual device group. Immediate postinsertion IUD pain may be related to the presenting diameter and insertional mechanism of the device. This pain is of short duration and after 3 minutes, the level of pain is independent of the type of device which has been inserted. The rapid diminution of pain at 3 minutes postinsertion indicates that the routine use of certain analgesic techniques, e.g., paracervical block before IUD insertion, is not justified. Pain following IUD insertion may provide a useful model for the study of various types of peripheral and centrally acting analgesics.
研究了未产妇女插入Copper 7 (Cu 7)或多负荷Copper 250-short (ML Cu 250-short)宫内节育器后即刻和3分钟的疼痛反应。35名妇女安装了Cu 7装置,23名妇女安装了ML Cu 250短装置。ML Cu 250-short组插入后即刻疼痛评分明显高于Cu 7组。两组插入后3分钟评分无显著差异。每个器械组的3分钟疼痛评分明显低于即时疼痛评分。宫内节育器插入后即刻疼痛可能与装置的呈现直径和插入机制有关。这种疼痛持续时间很短,3分钟后,疼痛程度与所插入的器械类型无关。插入后3分钟疼痛迅速减轻表明常规使用某些镇痛技术,例如,宫内节育器插入前宫颈旁阻滞,是不合理的。宫内节育器插入后的疼痛可能为研究各种类型的外周和中枢镇痛药提供有用的模型。