{"title":"Cesarean section IUD insertion.","authors":"V Ruiz-velasco, C Garcia, H Castro","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A trial was carried out on 154 selected volunteers who underwent cesarean section and then received an ML Cu 250 IUD during the operation. 56% of the operations were planned while 44% were not. The IUD was inserted in 65, 80, and 9 cases in the 1st, 2nd, and 3rd cesarean section, respectively. The patients were followed-up after 1, 3, 6, 12, and 24 months. Hospitalization time and postoperative morbidity did not increase with device insertion. Maternal lactation was not altered. 8% of the patients had postpartum bleeding which lasted more than 40 days. At the 1 year examination, 52% of the patients were menstruating normally while at 2 years, the percentage had increased to 62.5%. The acceptability, continuity, and efficiency of the contraceptive procedure proved successful. There were only 4 cases (2.6%) in which the device had to be removed for medical reasons (due largely to endometritis) and 8 cases (5.2%) because of patient desire (menstrual abnormalities). Spontaneous expulsion of the IUD occurred in 4 cases (2.6%). As of the present time, no pregnancies have been detected. The cesarean section insertion of an ML Cu 250 IUD produced excellent results and further, more widespread use is suggested.</p>","PeriodicalId":84493,"journal":{"name":"Contraceptive delivery systems","volume":"3 1","pages":"21-4"},"PeriodicalIF":0.0000,"publicationDate":"1982-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contraceptive delivery systems","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A trial was carried out on 154 selected volunteers who underwent cesarean section and then received an ML Cu 250 IUD during the operation. 56% of the operations were planned while 44% were not. The IUD was inserted in 65, 80, and 9 cases in the 1st, 2nd, and 3rd cesarean section, respectively. The patients were followed-up after 1, 3, 6, 12, and 24 months. Hospitalization time and postoperative morbidity did not increase with device insertion. Maternal lactation was not altered. 8% of the patients had postpartum bleeding which lasted more than 40 days. At the 1 year examination, 52% of the patients were menstruating normally while at 2 years, the percentage had increased to 62.5%. The acceptability, continuity, and efficiency of the contraceptive procedure proved successful. There were only 4 cases (2.6%) in which the device had to be removed for medical reasons (due largely to endometritis) and 8 cases (5.2%) because of patient desire (menstrual abnormalities). Spontaneous expulsion of the IUD occurred in 4 cases (2.6%). As of the present time, no pregnancies have been detected. The cesarean section insertion of an ML Cu 250 IUD produced excellent results and further, more widespread use is suggested.
一项试验选取了154名接受剖宫产手术的志愿者,并在手术期间接受了ML Cu 250宫内节育器。56%的手术是有计划的,44%的手术没有计划。第1、2、3次剖宫产分别置入宫内节育器65例、80例、9例。随访时间分别为1、3、6、12、24个月。住院时间和术后发病率不随装置插入而增加。母亲的泌乳没有改变。产后出血超过40天的占8%。1年检查时,52%的患者月经正常,2年检查时,这一比例增加到62.5%。避孕程序的可接受性、连续性和有效性证明是成功的。只有4例(2.6%)由于医疗原因(主要是由于子宫内膜炎)必须取出装置,8例(5.2%)由于患者的愿望(月经异常)。4例(2.6%)发生自然排出宫内节育器。到目前为止,还没有发现怀孕。剖宫产术中置入ML cu250宫内节育器效果良好,建议进一步推广应用。