Pressure monitoring of the femoral nerve during total hip replacement: an explanation for iatropathic palsy.

N Slater, R Singh, N Senasinghe, R Gore, T Goroszeniuk, D James
{"title":"Pressure monitoring of the femoral nerve during total hip replacement: an explanation for iatropathic palsy.","authors":"N Slater,&nbsp;R Singh,&nbsp;N Senasinghe,&nbsp;R Gore,&nbsp;T Goroszeniuk,&nbsp;D James","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Pressure changes around the femoral nerve were monitored throughout 10 consecutive primary total hip replacements to identify any surgical steps that might raise pressure around the nerve and be implicated in iatropathic palsy. The only notable variable was the patient himself/herself. The only step that consistently raised pressure around the nerve, sometimes to alarming levels, was use of a retractor sited on the anterior lip of the acetabulum. Pressure changes were modest in patients with an endomorphic body type suggesting relative protection from this injury by a thicker soft cushion.</p>","PeriodicalId":76058,"journal":{"name":"Journal of the Royal College of Surgeons of Edinburgh","volume":"45 4","pages":"231-3"},"PeriodicalIF":0.0000,"publicationDate":"2000-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Royal College of Surgeons of Edinburgh","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Pressure changes around the femoral nerve were monitored throughout 10 consecutive primary total hip replacements to identify any surgical steps that might raise pressure around the nerve and be implicated in iatropathic palsy. The only notable variable was the patient himself/herself. The only step that consistently raised pressure around the nerve, sometimes to alarming levels, was use of a retractor sited on the anterior lip of the acetabulum. Pressure changes were modest in patients with an endomorphic body type suggesting relative protection from this injury by a thicker soft cushion.

全髋关节置换术中股神经的压力监测:对医源性麻痹的解释。
在连续10次原发性全髋关节置换术中监测股神经周围的压力变化,以确定任何可能升高神经周围压力并涉及肌痛性麻痹的手术步骤。唯一值得注意的变量是病人本人。唯一能持续升高神经周围压力的方法是在髋臼前唇使用牵开器,有时会达到警戒水平。内源性体型患者的压力变化不大,提示较厚的软垫对这种损伤有相对的保护作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信