Assessment of coronary compensatory enlargement by three-dimensional intravascular ultrasound.

J D Klingensmith, D G Vince, B D Kuban, R Shekhar, E M Tuzcu, S E Nissen, J F Cornhill
{"title":"Assessment of coronary compensatory enlargement by three-dimensional intravascular ultrasound.","authors":"J D Klingensmith,&nbsp;D G Vince,&nbsp;B D Kuban,&nbsp;R Shekhar,&nbsp;E M Tuzcu,&nbsp;S E Nissen,&nbsp;J F Cornhill","doi":"10.1023/a:1006333619358","DOIUrl":null,"url":null,"abstract":"<p><p>Several techniques have been used to demonstrate that human arteries respond to atherosclerosis by increasing their total arterial area to prevent a decrease in blood flow. Three-dimensional reconstructions of coronary arteries can document this compensatory response accurately and specifically. Seven human coronary arteries were reconstructed using intravascular ultrasound and biplane angiography, and vessel geometries were quantified. In all seven vessels, as plaque area increased, overall vessel area increased (R = 0.986, 0.933, 0.984, 0.678, 0.763, 0.963, and 0.830), but luminal cross-sectional area did not significantly decrease. Focal compensatory enlargement was identified in each vessel, and in some cases this response appeared to occur until the vessel was 65% occluded. Luminal enlargement near the proximal ends was attributed to the natural taper of the vessel. The semi-automated, three-dimensional segmentation technique used in this study allows reproducible quantification, as there is no subjective manual tracing involved. Following the intravascular ultrasound transducer in time and space with biplane angiography allows for accurate reconstruction with or without automated pullback devices. Information on the rate of change of vessel measurements is also presented, which, when combined with visualization of accurate 3D geometry, provides a unique assessment of coronary compensatory enlargement. This reconstruction technique can be applied in a clinical environment with no major modification.</p>","PeriodicalId":77179,"journal":{"name":"International journal of cardiac imaging","volume":"16 2","pages":"87-98"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1006333619358","citationCount":"38","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of cardiac imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1006333619358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 38

Abstract

Several techniques have been used to demonstrate that human arteries respond to atherosclerosis by increasing their total arterial area to prevent a decrease in blood flow. Three-dimensional reconstructions of coronary arteries can document this compensatory response accurately and specifically. Seven human coronary arteries were reconstructed using intravascular ultrasound and biplane angiography, and vessel geometries were quantified. In all seven vessels, as plaque area increased, overall vessel area increased (R = 0.986, 0.933, 0.984, 0.678, 0.763, 0.963, and 0.830), but luminal cross-sectional area did not significantly decrease. Focal compensatory enlargement was identified in each vessel, and in some cases this response appeared to occur until the vessel was 65% occluded. Luminal enlargement near the proximal ends was attributed to the natural taper of the vessel. The semi-automated, three-dimensional segmentation technique used in this study allows reproducible quantification, as there is no subjective manual tracing involved. Following the intravascular ultrasound transducer in time and space with biplane angiography allows for accurate reconstruction with or without automated pullback devices. Information on the rate of change of vessel measurements is also presented, which, when combined with visualization of accurate 3D geometry, provides a unique assessment of coronary compensatory enlargement. This reconstruction technique can be applied in a clinical environment with no major modification.

三维血管内超声评价冠状动脉代偿性扩大。
一些技术已经被用来证明人类动脉对动脉粥样硬化的反应是通过增加动脉总面积来防止血流减少。冠状动脉的三维重建可以准确而具体地记录这种代偿反应。使用血管内超声和双翼血管造影重建7条人冠状动脉,并对血管几何形状进行量化。7条血管中,随着斑块面积的增加,总血管面积增加(R = 0.986、0.933、0.984、0.678、0.763、0.963、0.830),但管腔截面积没有明显减少。在每条血管中都发现了局灶性代偿性扩大,在某些情况下,这种反应一直持续到血管闭塞65%。近端管腔增大归因于血管的自然变细。本研究中使用的半自动三维分割技术允许可重复的量化,因为没有涉及主观的人工跟踪。在时间和空间上使用双翼血管造影跟踪血管内超声换能器,可以使用或不使用自动回拉装置进行精确重建。血管测量变化率的信息也被提出,当与精确的三维几何可视化相结合时,提供了冠状动脉代偿性扩大的独特评估。这种重建技术可以在临床环境中应用,不需要进行大的修改。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信