{"title":"Long-term audiometric follow-up of click-evoked auditory brainstem response in hearing-impaired infants.","authors":"R Schoonhoven,&nbsp;P J Lamoré,&nbsp;J A de Laat,&nbsp;J J Grote","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Conventional pure-tone thresholds were collected as determined at ages between 4 and 8 years from a group of 163 infants, tested by auditory brainstem response (ABR) in the age range between 1 and 3 years old for objective hearing assessment. The subjects suffered from a variety of degrees and types of sensorineural hearing impairment. The prognostic value of the ABR peak V thresholds in response to 0.1 ms clicks with respect to the behavioural thresholds at octave frequencies from 125 to 8,000 Hz obtained later is evaluated. Correlation between ABR and behavioural thresholds is largest in the 1,000- to 8,000-Hz frequency range. Predicted pure-tone audiograms (mean and SD) were determined for each 10-dB class of ABR thresholds. SDs are in the order of 15 to 18 dB in the 500- to 4,000-Hz range and slightly higher at adjacent frequencies (i.e., somewhat larger than in comparable adult studies). Mean pure-tone thresholds in the 1,000- to 8,000-Hz frequency range are up to 20 dB worse than ABR thresholds, which is opposite to findings in normally-hearing subjects. Thus, with an increasing degree of sensorineural hearing impairment, pure-tone thresholds increase at a significantly higher rate than ABR thresholds. The observation is explained in terms of reduced temporal integration in cochlear hearing loss. ABR thresholds worse than 80 dB nHL are demonstrated to have very limited predictive value with respect to the amount of residual hearing, not only in the low- but also in the high-frequency range. The presence of otitis media during ABR testing is shown to make estimation errors increase to more than 25 dB (SD).</p>","PeriodicalId":75571,"journal":{"name":"Audiology : official organ of the International Society of Audiology","volume":"39 3","pages":"135-45"},"PeriodicalIF":0.0000,"publicationDate":"2000-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology : official organ of the International Society of Audiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Conventional pure-tone thresholds were collected as determined at ages between 4 and 8 years from a group of 163 infants, tested by auditory brainstem response (ABR) in the age range between 1 and 3 years old for objective hearing assessment. The subjects suffered from a variety of degrees and types of sensorineural hearing impairment. The prognostic value of the ABR peak V thresholds in response to 0.1 ms clicks with respect to the behavioural thresholds at octave frequencies from 125 to 8,000 Hz obtained later is evaluated. Correlation between ABR and behavioural thresholds is largest in the 1,000- to 8,000-Hz frequency range. Predicted pure-tone audiograms (mean and SD) were determined for each 10-dB class of ABR thresholds. SDs are in the order of 15 to 18 dB in the 500- to 4,000-Hz range and slightly higher at adjacent frequencies (i.e., somewhat larger than in comparable adult studies). Mean pure-tone thresholds in the 1,000- to 8,000-Hz frequency range are up to 20 dB worse than ABR thresholds, which is opposite to findings in normally-hearing subjects. Thus, with an increasing degree of sensorineural hearing impairment, pure-tone thresholds increase at a significantly higher rate than ABR thresholds. The observation is explained in terms of reduced temporal integration in cochlear hearing loss. ABR thresholds worse than 80 dB nHL are demonstrated to have very limited predictive value with respect to the amount of residual hearing, not only in the low- but also in the high-frequency range. The presence of otitis media during ABR testing is shown to make estimation errors increase to more than 25 dB (SD).

听障婴儿点击诱发的听觉脑干反应的长期听力学随访。
收集163名4 - 8岁婴儿的常规纯音阈值,并对1 - 3岁的婴儿进行听觉脑干反应(ABR)测试,用于客观听力评估。受试者患有不同程度和类型的感觉神经性听力障碍。我们评估了响应于0.1 ms点击的ABR峰值V阈值相对于随后获得的125至8,000 Hz的倍频频率的行为阈值的预测价值。ABR和行为阈值之间的相关性在1000至8000赫兹的频率范围内最大。预测的纯音听力图(平均值和标准差)被确定为每个10分贝类别的ABR阈值。在500至4,000 hz范围内,SDs为15至18 dB,在相邻频率上略高(即,略大于可比的成人研究)。在1,000- 8,000 hz频率范围内,平均纯音阈值比ABR阈值差20 dB,这与听力正常受试者的结果相反。因此,随着感音神经性听力障碍程度的增加,纯音阈值的增加速度明显高于ABR阈值。这一观察结果可以从耳蜗听力损失的时间整合能力降低的角度来解释。低于80 dB nHL的ABR阈值被证明对残余听力量的预测价值非常有限,不仅在低频段,而且在高频频段。在ABR测试中,中耳炎的存在会使估计误差增加到25 dB (SD)以上。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信