Mechanical properties and imaging characteristics of remanufactured intravascular ultrasound catheters.

R Hoffmann, P Haager, G Mintz, H Klues
{"title":"Mechanical properties and imaging characteristics of remanufactured intravascular ultrasound catheters.","authors":"R Hoffmann,&nbsp;P Haager,&nbsp;G Mintz,&nbsp;H Klues","doi":"10.1023/a:1006310612175","DOIUrl":null,"url":null,"abstract":"<p><p>Intravascular ultrasound (IVUS) as a routine device in interventional cardiology is handicapped by its high price. 19 factory-made, 'remanufactured' IVUS catheters which consist of sterilized, used phased-array IVUS transducers inserted into a new catheter shaft were compared with 23 new IVUS catheters. 3 mechanical and 4 imaging characteristics were assessed on a 5 point scale (1 = unacceptable, 5 = excellent). Mechanical as well as imaging properties of 'remanufactured' IVUS catheter were comparable to new catheters with excellent ratings for each of the evaluated characteristics in 38 to 94% of 'remanufactured' catheters and 50 to 96% of new catheters. The initial failure rate for 'remanufactured' IVUS catheters was 31.6% vs. 4.3% for new catheters (P < 0.05). Overall failure rate was 47.3% for \"remanufactured\" catheters vs. 8.7% for new catheters (P < 0.05). The failure was due to an electronic connecting problem occurring during mechanical stress to the IVUS catheter. In conclusion, 'remanufactured' IVUS catheters offer mechanical and imaging characteristics which are comparable to new catheters. Improvements in the 'remanufacturing' process to resolve the high rate of electronic connecting problems may make this a promising approach to substantially lower the price of IVUS catheters.</p>","PeriodicalId":77179,"journal":{"name":"International journal of cardiac imaging","volume":"16 1","pages":"23-7"},"PeriodicalIF":0.0000,"publicationDate":"2000-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1006310612175","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of cardiac imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1006310612175","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Intravascular ultrasound (IVUS) as a routine device in interventional cardiology is handicapped by its high price. 19 factory-made, 'remanufactured' IVUS catheters which consist of sterilized, used phased-array IVUS transducers inserted into a new catheter shaft were compared with 23 new IVUS catheters. 3 mechanical and 4 imaging characteristics were assessed on a 5 point scale (1 = unacceptable, 5 = excellent). Mechanical as well as imaging properties of 'remanufactured' IVUS catheter were comparable to new catheters with excellent ratings for each of the evaluated characteristics in 38 to 94% of 'remanufactured' catheters and 50 to 96% of new catheters. The initial failure rate for 'remanufactured' IVUS catheters was 31.6% vs. 4.3% for new catheters (P < 0.05). Overall failure rate was 47.3% for "remanufactured" catheters vs. 8.7% for new catheters (P < 0.05). The failure was due to an electronic connecting problem occurring during mechanical stress to the IVUS catheter. In conclusion, 'remanufactured' IVUS catheters offer mechanical and imaging characteristics which are comparable to new catheters. Improvements in the 'remanufacturing' process to resolve the high rate of electronic connecting problems may make this a promising approach to substantially lower the price of IVUS catheters.

再制造血管内超声导管的力学性能和影像学特征。
血管内超声(IVUS)作为介入心脏病学的常规设备,由于其价格昂贵而受到限制。将19根工厂制造的“再制造”IVUS导管与23根新的IVUS导管进行比较,这些IVUS导管由灭菌的、使用过的相控阵IVUS传感器插入到新的导管轴中。3个力学特征和4个影像学特征以5分制进行评估(1 =不可接受,5 =优秀)。“再制造”IVUS导管的机械性能和成像性能与新导管相当,在38 - 94%的“再制造”导管和50 - 96%的新导管中,每项评估特征都具有优异的评分。“再制造”IVUS导管的初始失败率为31.6%,而新导管的失败率为4.3% (P < 0.05)。“再制造”导管的总体失败率为47.3%,而新导管的失败率为8.7% (P < 0.05)。失败的原因是在对IVUS导管施加机械应力时发生的电子连接问题。总之,“再制造”IVUS导管具有与新导管相当的机械和成像特性。“再制造”过程的改进,以解决高比率的电子连接问题,可能使这一有希望的方法大大降低IVUS导管的价格。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信