{"title":"[Predictive value of nocturnal pulse oximetry in sleep apnea screening].","authors":"R Nuber, J Vavrina, W Karrer","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The monitoring of overnight oxygen saturation is widely used for sleep apnoea screening. The point of this screening has been questioned as a wide range of sensitivity has been reported in the literature. In a prospective study 70 subjects presenting with a possible sleep apnoea-hypopnoea syndrome had overnight oximetry followed by polysomnography 2 to 4 months later. Compared to polysomnography, the sensitivity of oximetry for sleep apnoea-hypopnoea was 85.2%, the specificity 77.8% and the predictive value positive 96.3%. When short, non-significant, repetitive desaturations have been declared pathologic, sensitivity increased to 91.8%. In the hands of an expert user, oximetry represents an excellent instrument for detecting patients with sleep apnoea-hypopnoea. Patients with pathological nocturnal oximetry are candidates for nCPAP treatment and therefore should undergo a sleep laboratory investigation.</p>","PeriodicalId":76532,"journal":{"name":"Schweizerische medizinische Wochenschrift. Supplementum","volume":"116 ","pages":"120S-122S"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Schweizerische medizinische Wochenschrift. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The monitoring of overnight oxygen saturation is widely used for sleep apnoea screening. The point of this screening has been questioned as a wide range of sensitivity has been reported in the literature. In a prospective study 70 subjects presenting with a possible sleep apnoea-hypopnoea syndrome had overnight oximetry followed by polysomnography 2 to 4 months later. Compared to polysomnography, the sensitivity of oximetry for sleep apnoea-hypopnoea was 85.2%, the specificity 77.8% and the predictive value positive 96.3%. When short, non-significant, repetitive desaturations have been declared pathologic, sensitivity increased to 91.8%. In the hands of an expert user, oximetry represents an excellent instrument for detecting patients with sleep apnoea-hypopnoea. Patients with pathological nocturnal oximetry are candidates for nCPAP treatment and therefore should undergo a sleep laboratory investigation.