Macroamylase detection in serum using selective precipitation: a rapid and reliable assay.

M Ventrucci, A Cipolla, M Middonno, C Racchini, E Pollini, G V Melzi d'Eril
{"title":"Macroamylase detection in serum using selective precipitation: a rapid and reliable assay.","authors":"M Ventrucci,&nbsp;A Cipolla,&nbsp;M Middonno,&nbsp;C Racchini,&nbsp;E Pollini,&nbsp;G V Melzi d'Eril","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aim: </strong>Available assays for measurement of pancreatic isoamylase in serum based on specific immunoinhibition of salivary fraction are unable to detect macroamylase. We combined a polyethylene glycol test which identifies macroamylase by selective precipitation with an automated assay for total amylase and pancreatic isoamylase measurement.</p><p><strong>Methods: </strong>We analysed 24 sera proven positive for macroamylase using gel filtration chromatography and 80 negative sera. Precipitation of macroamylase with polyethylene glycol, colourimetric measurement of total amylase activity and immunoinhibition for the determination of pancreatic isoamylase were carried out.</p><p><strong>Results: </strong>Macroamylasaemic sera showed precipitation of at least 71% of the amylase activity, while sera with normal-sized amylase exhibited a maximum of 61%. In all the macroamylasaemic sera but two, the immunoinhibition test showed a rise in pancreatic isoamylase, which was found to be the prevalent fraction in 16. In 21 out of 24 sera with macroamylase and 67 out of 80 with normal-sized amylase, the precipitated amylase activity was also measured after immunoinhibition of non pancreatic activity. In macroamylasaemic sera, the percentage of precipitated pancreatic isoamylase activity ranged from 75% to 98%, while in samples with normal-sized amylase it was less than 71%.</p><p><strong>Conclusions: </strong>Polyethylene glycol precipitation can easily be combined with automated assays for the determination of pancreatic isoamylase and should be carried out whenever dealing with hyperamylasaemia of unclear origin.</p>","PeriodicalId":79501,"journal":{"name":"Italian journal of gastroenterology and hepatology","volume":"31 9","pages":"846-9"},"PeriodicalIF":0.0000,"publicationDate":"1999-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Italian journal of gastroenterology and hepatology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aim: Available assays for measurement of pancreatic isoamylase in serum based on specific immunoinhibition of salivary fraction are unable to detect macroamylase. We combined a polyethylene glycol test which identifies macroamylase by selective precipitation with an automated assay for total amylase and pancreatic isoamylase measurement.

Methods: We analysed 24 sera proven positive for macroamylase using gel filtration chromatography and 80 negative sera. Precipitation of macroamylase with polyethylene glycol, colourimetric measurement of total amylase activity and immunoinhibition for the determination of pancreatic isoamylase were carried out.

Results: Macroamylasaemic sera showed precipitation of at least 71% of the amylase activity, while sera with normal-sized amylase exhibited a maximum of 61%. In all the macroamylasaemic sera but two, the immunoinhibition test showed a rise in pancreatic isoamylase, which was found to be the prevalent fraction in 16. In 21 out of 24 sera with macroamylase and 67 out of 80 with normal-sized amylase, the precipitated amylase activity was also measured after immunoinhibition of non pancreatic activity. In macroamylasaemic sera, the percentage of precipitated pancreatic isoamylase activity ranged from 75% to 98%, while in samples with normal-sized amylase it was less than 71%.

Conclusions: Polyethylene glycol precipitation can easily be combined with automated assays for the determination of pancreatic isoamylase and should be carried out whenever dealing with hyperamylasaemia of unclear origin.

选择性沉淀法检测血清中巨淀粉酶:一种快速可靠的方法。
背景和目的:现有的基于唾液部分特异性免疫抑制的血清胰腺异淀粉酶测定方法无法检测巨淀粉酶。我们结合了聚乙二醇测试,通过选择性沉淀识别大淀粉酶与总淀粉酶和胰腺异淀粉酶的自动测定。方法:采用凝胶过滤层析法对24例大淀粉酶阳性血清和80例大淀粉酶阴性血清进行分析。用聚乙二醇沉淀大淀粉酶,用比色法测定总淀粉酶活性,用免疫抑制法测定胰腺异淀粉酶。结果:大淀粉酶血症血清显示至少71%的淀粉酶活性沉淀,而正常大小的淀粉酶血清显示最多61%。在所有的大淀粉酶血症血清中,除两种外,免疫抑制试验显示胰腺异淀粉酶升高,这是16年发现的普遍部分。在24份含有大淀粉酶的血清中有21份和80份含有正常大小淀粉酶的血清中有67份,在免疫抑制非胰腺活性后也测量了沉淀淀粉酶的活性。在大淀粉酶血症的血清中,胰腺异淀粉酶活性的沉淀百分比在75%到98%之间,而在正常淀粉酶的样本中,这一比例不到71%。结论:聚乙二醇沉淀法可方便地与自动测定法联合用于胰腺异淀粉酶的测定,在处理来历不明的高淀粉酶血症时应采用聚乙二醇沉淀法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信