M P van der Woord, H Kromhout, L Barregård, P Jonsson
{"title":"Within-day variability of magnetic fields among electric utility workers: consequences for measurement strategies.","authors":"M P van der Woord, H Kromhout, L Barregård, P Jonsson","doi":"10.1080/00028899908984493","DOIUrl":null,"url":null,"abstract":"<p><p>Occupational exposure to 50-Hz magnetic fields was surveyed among electric utility workers to investigate (1) components of exposure variability, (2) patterns of autocorrelation between short-term measurements, and (3) imprecision and misclassification due to short-term measurements. Spot measurements every 10 seconds during 81 working days were analyzed for 42 electric utility workers from 10 occupational subgroups and during 8 working days for 4 office workers from the same company. For the 8-hour time-weighted average (TWA) magnetic fields, the variability was partitioned into its components: within workers, between workers, and between groups. For spot measurements of magnetic fields, the within-day variance component also was examined. Autocorrelation functions were determined and numbers of short-term measurements necessary for reliable estimates of 8-hour TWA magnetic fields were assessed. Spot measurements of magnetic fields, as well as 8-hour TWA magnetic fields, were approximately log normally distributed among workers. The mean exposure to magnetic fields was 0.47 microT (n = 81 days) in electric utility workers and 0.12 microT (n = 8 days) in office workers. A large fraction, 76% of the spot measurements total variance, could be attributed to variability within days. For the 8-hour TWA magnetic fields, between-group variability was small and of the same magnitude as between-worker variability. Significant autocorrelations between short-term averages of 7.5, 15, and 30 minutes were present, when taken within periods of 30 minutes. One-hour averages showed no autocorrelation. Simulations showed that, due to high within-day variability and autocorrelation, a limited number of short-term measurements of magnetic fields in electric utility workers are likely to result in imprecise estimates of 8-hour TWA magnetic fields. Measurement strategies relying on short-term (spot) measurements are therefore likely to result in misclassification of exposure and consequently absent or spurious exposure-response relations.</p>","PeriodicalId":7930,"journal":{"name":"American Industrial Hygiene Association journal","volume":"60 6","pages":"713-9"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00028899908984493","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Industrial Hygiene Association journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00028899908984493","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
Abstract
Occupational exposure to 50-Hz magnetic fields was surveyed among electric utility workers to investigate (1) components of exposure variability, (2) patterns of autocorrelation between short-term measurements, and (3) imprecision and misclassification due to short-term measurements. Spot measurements every 10 seconds during 81 working days were analyzed for 42 electric utility workers from 10 occupational subgroups and during 8 working days for 4 office workers from the same company. For the 8-hour time-weighted average (TWA) magnetic fields, the variability was partitioned into its components: within workers, between workers, and between groups. For spot measurements of magnetic fields, the within-day variance component also was examined. Autocorrelation functions were determined and numbers of short-term measurements necessary for reliable estimates of 8-hour TWA magnetic fields were assessed. Spot measurements of magnetic fields, as well as 8-hour TWA magnetic fields, were approximately log normally distributed among workers. The mean exposure to magnetic fields was 0.47 microT (n = 81 days) in electric utility workers and 0.12 microT (n = 8 days) in office workers. A large fraction, 76% of the spot measurements total variance, could be attributed to variability within days. For the 8-hour TWA magnetic fields, between-group variability was small and of the same magnitude as between-worker variability. Significant autocorrelations between short-term averages of 7.5, 15, and 30 minutes were present, when taken within periods of 30 minutes. One-hour averages showed no autocorrelation. Simulations showed that, due to high within-day variability and autocorrelation, a limited number of short-term measurements of magnetic fields in electric utility workers are likely to result in imprecise estimates of 8-hour TWA magnetic fields. Measurement strategies relying on short-term (spot) measurements are therefore likely to result in misclassification of exposure and consequently absent or spurious exposure-response relations.