Validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.
E Wellnhofer, A Wahle, I Mugaragu, J Gross, H Oswald, E Fleck
{"title":"Validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.","authors":"E Wellnhofer, A Wahle, I Mugaragu, J Gross, H Oswald, E Fleck","doi":"10.1023/a:1006322609072","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>The goal of the study was the validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.</p><p><strong>Methods: </strong>The accuracy was tested in a complex phantom. In vivo, inter- and intraobserver agreement were assessed by analysis of routine angiograms. The sensitivity was evaluated using angiograms of patients having diagnostic vasoactive pharmacological intervention. Two-dimensional quantitative coronary angiography (2-D QCA) and 3-D QCA were compared concerning the accuracy of diameter evaluation.</p><p><strong>Results: </strong>3-D QCA yields accurate results (< 3% error) even based on nonorthogonal views, provided that projections parallel to the object are avoided. The inter- and intraobserver variability is < or = 5%. Significant (p < 0.01) changes of the volume (36-39%) and the diameter (19-21%) are detected following pharmacological intervention. 2-D QCA and 3-D QCA agree in short matched segments without foreshortening. 2-D QCA is rather sensitive to foreshortening and not suitable for evaluation of diameters of longer branches or total coronaries.</p><p><strong>Conclusion: </strong>3-D QCA permits an accurate, reproducible and sensitive comprehensive three-dimensional geometric analysis of the coronaries and is superior to 2-D QCA with respect to extended diameter evaluation.</p>","PeriodicalId":77179,"journal":{"name":"International journal of cardiac imaging","volume":"15 5","pages":"339-53; discussion 355-6"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1006322609072","citationCount":"59","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of cardiac imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1006322609072","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 59
Abstract
Unlabelled: The goal of the study was the validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.
Methods: The accuracy was tested in a complex phantom. In vivo, inter- and intraobserver agreement were assessed by analysis of routine angiograms. The sensitivity was evaluated using angiograms of patients having diagnostic vasoactive pharmacological intervention. Two-dimensional quantitative coronary angiography (2-D QCA) and 3-D QCA were compared concerning the accuracy of diameter evaluation.
Results: 3-D QCA yields accurate results (< 3% error) even based on nonorthogonal views, provided that projections parallel to the object are avoided. The inter- and intraobserver variability is < or = 5%. Significant (p < 0.01) changes of the volume (36-39%) and the diameter (19-21%) are detected following pharmacological intervention. 2-D QCA and 3-D QCA agree in short matched segments without foreshortening. 2-D QCA is rather sensitive to foreshortening and not suitable for evaluation of diameters of longer branches or total coronaries.
Conclusion: 3-D QCA permits an accurate, reproducible and sensitive comprehensive three-dimensional geometric analysis of the coronaries and is superior to 2-D QCA with respect to extended diameter evaluation.