{"title":"Reduction in range of movement can increase maximum voluntary eccentric forces for the human knee extensor muscles.","authors":"H M Holder-Powell, O M Rutherford","doi":"10.1007/s004210050624","DOIUrl":null,"url":null,"abstract":"<p><p>Using the KinCom 500H isokinetic dynamometer the first part of this study measured the characteristics of the force velocity relationship curve for the human knee extensors between -1.57 (eccentric) and 3.67 (concentric) rads x s(-1) (-90 and 210 degrees s(1)) for both legs in 4 subjects. A significant increase in force generation was seen in eccentric activity at 0.52 rads x s(-1) (30 degrees s(-1)) but not at 1.57 rads x s(-1) (90 degrees s(-1)) compared to maximum voluntary isometric force (P < 0.005). This increase was, however, lower than would be expected from the classical force-velocity relationship. The second part of the study examined whether restricting the range of movement was able to further increase the eccentric forces. In a further 6 subjects, the eccentric contractions were repeated during either an 80 degrees (15-95 degrees flexion) and a 50 degrees (45-95 degrees flexion) range of movement. Significant increases in force were seen over the shorter range of movement at 0.52 rads x s(-1) (30 degrees s(-1)) (P = 0.006) and 1.57 rads x s(-1) (90 degrees s(-1)) (P < 0.001).</p>","PeriodicalId":11936,"journal":{"name":"European Journal of Applied Physiology and Occupational Physiology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/s004210050624","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Applied Physiology and Occupational Physiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s004210050624","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12
Abstract
Using the KinCom 500H isokinetic dynamometer the first part of this study measured the characteristics of the force velocity relationship curve for the human knee extensors between -1.57 (eccentric) and 3.67 (concentric) rads x s(-1) (-90 and 210 degrees s(1)) for both legs in 4 subjects. A significant increase in force generation was seen in eccentric activity at 0.52 rads x s(-1) (30 degrees s(-1)) but not at 1.57 rads x s(-1) (90 degrees s(-1)) compared to maximum voluntary isometric force (P < 0.005). This increase was, however, lower than would be expected from the classical force-velocity relationship. The second part of the study examined whether restricting the range of movement was able to further increase the eccentric forces. In a further 6 subjects, the eccentric contractions were repeated during either an 80 degrees (15-95 degrees flexion) and a 50 degrees (45-95 degrees flexion) range of movement. Significant increases in force were seen over the shorter range of movement at 0.52 rads x s(-1) (30 degrees s(-1)) (P = 0.006) and 1.57 rads x s(-1) (90 degrees s(-1)) (P < 0.001).
本研究的第一部分使用KinCom 500H等速测力仪测量了4名受试者双腿人体膝关节伸肌在-1.57(偏心)和3.67(同心)rad x s(-1)(-90和210度s(1))之间的力-速度关系曲线特征。与最大自主等距力相比,在0.52 rads x s(-1)(30°s(-1))时,偏心活动的力产生显著增加,而在1.57 rads x s(-1)(90°s(-1))时则没有显著增加(P < 0.005)。然而,这一增加比经典的力-速度关系所预期的要低。研究的第二部分考察了限制运动范围是否能够进一步增加偏心力。在另外6名受试者中,在80度(15-95度屈曲)和50度(45-95度屈曲)的运动范围内重复偏心收缩。在较短的运动范围内,力的显著增加为0.52 rad x s(-1)(30°s(-1)) (P = 0.006)和1.57 rad x s(-1)(90°s(-1)) (P < 0.001)。