In vitro elution of vancomycin from biodegradable beads.

S J Liu, S W Ueng, E C Chan, S S Lin, C H Tsai, F C Wei, C H Shih
{"title":"In vitro elution of vancomycin from biodegradable beads.","authors":"S J Liu,&nbsp;S W Ueng,&nbsp;E C Chan,&nbsp;S S Lin,&nbsp;C H Tsai,&nbsp;F C Wei,&nbsp;C H Shih","doi":"10.1002/(sici)1097-4636(1999)48:5<613::aid-jbm4>3.0.co;2-#","DOIUrl":null,"url":null,"abstract":"<p><p>The current antibiotics delivery system for orthopedic infection treatment uses polymethylmethacrylate (PMMA) beads as a drug release. However the nonbiodegradable nature of the PMMA necessitates a second operation to remove the beads. This article explores the alternative of using biodegradable polymers as antibiotic beads for a long-term drug release. The effect of different processing factors on the release rate of the beads was investigated. To manufacture an antibiotic bead, polylactide-polyglycolide copolymers were mixed with vancomycin. The mixture was compressed and sintered at 55 degrees C to form beads of different sizes. An elution method was employed to characterize the release rate of antibiotic over a 35-day period at 37 degrees C. Biodegradable beads released high concentrations of antibiotic (well above the breakpoint sensitivity concentration) in vitro for the period of time needed to treat bone infection; i.e., 4-6 weeks. A bacterial inhibition test was carried out to determine the relative activity of the released antibiotics. The diameter of the sample inhibition zone ranged from 6.5-10 mm, which is equivalent to 12.5-100% of relative activity. By changing the processing parameters, we were able to control the release rate of the beads. This provides advantages of meeting the specific antibiotics requirement for patients with various surgical infections.</p>","PeriodicalId":15159,"journal":{"name":"Journal of biomedical materials research","volume":"48 5","pages":"613-20"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(sici)1097-4636(1999)48:5<613::aid-jbm4>3.0.co;2-#","citationCount":"47","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical materials research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(sici)1097-4636(1999)48:5<613::aid-jbm4>3.0.co;2-#","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 47

Abstract

The current antibiotics delivery system for orthopedic infection treatment uses polymethylmethacrylate (PMMA) beads as a drug release. However the nonbiodegradable nature of the PMMA necessitates a second operation to remove the beads. This article explores the alternative of using biodegradable polymers as antibiotic beads for a long-term drug release. The effect of different processing factors on the release rate of the beads was investigated. To manufacture an antibiotic bead, polylactide-polyglycolide copolymers were mixed with vancomycin. The mixture was compressed and sintered at 55 degrees C to form beads of different sizes. An elution method was employed to characterize the release rate of antibiotic over a 35-day period at 37 degrees C. Biodegradable beads released high concentrations of antibiotic (well above the breakpoint sensitivity concentration) in vitro for the period of time needed to treat bone infection; i.e., 4-6 weeks. A bacterial inhibition test was carried out to determine the relative activity of the released antibiotics. The diameter of the sample inhibition zone ranged from 6.5-10 mm, which is equivalent to 12.5-100% of relative activity. By changing the processing parameters, we were able to control the release rate of the beads. This provides advantages of meeting the specific antibiotics requirement for patients with various surgical infections.

万古霉素在生物可降解微球中的体外洗脱。
目前用于骨科感染治疗的抗生素递送系统使用聚甲基丙烯酸甲酯(PMMA)微球作为药物释放。然而,PMMA的不可生物降解性质需要第二次手术来去除珠子。这篇文章探讨了使用生物可降解聚合物作为抗生素珠长期药物释放的替代方案。考察了不同工艺条件对微球释放速度的影响。将聚乳酸-聚乙醇酸共聚物与万古霉素混合制备抗生素微球。将混合物压缩并在55℃下烧结,形成不同大小的珠子。采用洗脱法表征抗生素在37℃下35天内的释放率。可生物降解的微球在体外释放高浓度抗生素(远高于断点敏感浓度),用于治疗骨感染所需的一段时间;即4-6周。进行抑菌试验,测定所释抗生素的相对活性。样品抑制带直径为6.5 ~ 10 mm,相当于相对活性的12.5 ~ 100%。通过改变工艺参数,我们能够控制微球的释放速度。这为满足各种手术感染患者的特定抗生素需求提供了优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信