Assessment of the normal adult right ventricular diastolic function using M-mode echocardiographic measurement of tricuspid ring motion.

Y Nakagawa, S Fujimoto, R Mizuno, A Kimura, T Hashimoto, H Nakano, K Dohi
{"title":"Assessment of the normal adult right ventricular diastolic function using M-mode echocardiographic measurement of tricuspid ring motion.","authors":"Y Nakagawa,&nbsp;S Fujimoto,&nbsp;R Mizuno,&nbsp;A Kimura,&nbsp;T Hashimoto,&nbsp;H Nakano,&nbsp;K Dohi","doi":"10.1023/a:1006127128984","DOIUrl":null,"url":null,"abstract":"<p><p>Right ventricular function can be evaluated echocardiographically by assessing the longitudinal motion of the tricuspid ring recorded in the apical four chamber view. In this study, we applied this technique to assess the right ventricular diastolic function in 10 healthy Japanese men (mean age: 28 +/- 6 years; age range: 20-43 years). Echocardiographic studies were performed with a phased-array imaging system using a 2.5 MHz probe. Tricuspid ring motion was measured by two-dimensional echo guided M-mode echocardiogram of the right lateral tricuspid ring. The excursion of the tricuspid ring during early diastole (DS; mm) and the peak rate of change of the excursion (dS/dt; mm/sec) were measured. We also assessed the right ventricular function by cine magnetic resonance imaging (MRI). Cine gradient echo images were obtained along the short axis of the right ventricle. The right ventricular volume at each phase of the cardiac cycle was calculated by Simpson's method and time-volume curves were constructed. The peak filling rate (dV/dt; ml/s) was determined from these time-volume curves. The dS was 12.8 +/- 2.5 mm, dS/dt was 132 +/- 27 mm/sec and dV/dt was 269 +/- 66 ml/s. There were significant positive correlations between dS and dV/dt (r = 0.80, P < 0.01), and between dS/dt and dV/dt (r = 0.45, P < 0.05). Based on our results, M-mode echocardiographic measurements of tricuspid ring motion may be used to assess the right ventricular diastolic function.</p>","PeriodicalId":77179,"journal":{"name":"International journal of cardiac imaging","volume":"14 6","pages":"391-5"},"PeriodicalIF":0.0000,"publicationDate":"1998-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1006127128984","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of cardiac imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1006127128984","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Right ventricular function can be evaluated echocardiographically by assessing the longitudinal motion of the tricuspid ring recorded in the apical four chamber view. In this study, we applied this technique to assess the right ventricular diastolic function in 10 healthy Japanese men (mean age: 28 +/- 6 years; age range: 20-43 years). Echocardiographic studies were performed with a phased-array imaging system using a 2.5 MHz probe. Tricuspid ring motion was measured by two-dimensional echo guided M-mode echocardiogram of the right lateral tricuspid ring. The excursion of the tricuspid ring during early diastole (DS; mm) and the peak rate of change of the excursion (dS/dt; mm/sec) were measured. We also assessed the right ventricular function by cine magnetic resonance imaging (MRI). Cine gradient echo images were obtained along the short axis of the right ventricle. The right ventricular volume at each phase of the cardiac cycle was calculated by Simpson's method and time-volume curves were constructed. The peak filling rate (dV/dt; ml/s) was determined from these time-volume curves. The dS was 12.8 +/- 2.5 mm, dS/dt was 132 +/- 27 mm/sec and dV/dt was 269 +/- 66 ml/s. There were significant positive correlations between dS and dV/dt (r = 0.80, P < 0.01), and between dS/dt and dV/dt (r = 0.45, P < 0.05). Based on our results, M-mode echocardiographic measurements of tricuspid ring motion may be used to assess the right ventricular diastolic function.

用m型超声心动图测量三尖瓣环运动评价正常成人右心室舒张功能。
右心室功能可以通过超声心动图评估记录在心尖四室视图的三尖瓣环的纵向运动来评估。在这项研究中,我们应用该技术评估了10名健康的日本男性(平均年龄:28±6岁;年龄范围:20-43岁)。超声心动图研究采用2.5 MHz探头相控阵成像系统进行。采用二维超声引导下右外侧三尖瓣环m型超声心动图测量三尖瓣环运动。舒张早期三尖瓣环漂移(DS;mm)和偏移的峰值变化率(dS/dt;Mm /sec)。我们还通过电影磁共振成像(MRI)评估右心室功能。沿右心室短轴行梯度回波成像。采用辛普森法计算心周期各期右心室容积,并构建时间-容积曲线。峰值填充率(dV/dt;Ml /s)由时间-体积曲线测定。dS为12.8 +/- 2.5 mm, dS/dt为132 +/- 27 mm/s, dV/dt为269 +/- 66 ml/s。dS与dV/dt呈显著正相关(r = 0.80, P < 0.01), dS/dt与dV/dt呈显著正相关(r = 0.45, P < 0.05)。基于我们的结果,m型超声心动图测量三尖瓣环运动可用于评估右心室舒张功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信