Intelligibility of vowels produced by post-lingually deafened cochlear implant users.

M C Langereis, A J Bosman, A F van Olphen, G F Smoorenburg
{"title":"Intelligibility of vowels produced by post-lingually deafened cochlear implant users.","authors":"M C Langereis,&nbsp;A J Bosman,&nbsp;A F van Olphen,&nbsp;G F Smoorenburg","doi":"10.3109/00206099909073025","DOIUrl":null,"url":null,"abstract":"<p><p>The present study addresses the effect of cochlear implantation on the intelligibility of vowels produced by 20 post-lingually deafened Dutch subjects. All subjects received the Nucleus-22 cochlear implant (3 WSP and 17 MSP processors). Speech recordings were made pre-implantation and three and twelve months post-implantation with the implant switched on and off. Vowel intelligibility (monophthongs only) was determined using a panel of listeners. For all implanted subjects intelligibility was measured in a noisy background. For seven poorly speaking subjects it was also measured in a quiet background. After implantation with the Nucleus-22 device the results showed that vowel intelligibility, measured for all subjects in a noisy background, increased for most of them (about 15), while it increased for about half the number of poorly speaking subjects measured in a quiet background. Twelve months after implantation vowel intelligibility, measured for all subjects in noise, appeared to be based on first and second formant information. This was also found for the subgroup of seven subjects performing poorly pre-implantation when analysed separately. However, vowel intelligibility for this subgroup, when measured in a quiet background, was based also on vowel duration. The differences between the overall result in noise and the results of the subgroup in quiet should be attributed mainly to the noise and not to aspects of poor speech production in the subgroup. In addition, this study addresses the relationship between the intelligibility scores and objective measurements of vowel quality performed in a previous study. The results showed that the vowel intelligibility scores are mainly determined by the position of the second formant frequencies.</p>","PeriodicalId":75571,"journal":{"name":"Audiology : official organ of the International Society of Audiology","volume":"38 4","pages":"206-24"},"PeriodicalIF":0.0000,"publicationDate":"1999-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/00206099909073025","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology : official organ of the International Society of Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/00206099909073025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The present study addresses the effect of cochlear implantation on the intelligibility of vowels produced by 20 post-lingually deafened Dutch subjects. All subjects received the Nucleus-22 cochlear implant (3 WSP and 17 MSP processors). Speech recordings were made pre-implantation and three and twelve months post-implantation with the implant switched on and off. Vowel intelligibility (monophthongs only) was determined using a panel of listeners. For all implanted subjects intelligibility was measured in a noisy background. For seven poorly speaking subjects it was also measured in a quiet background. After implantation with the Nucleus-22 device the results showed that vowel intelligibility, measured for all subjects in a noisy background, increased for most of them (about 15), while it increased for about half the number of poorly speaking subjects measured in a quiet background. Twelve months after implantation vowel intelligibility, measured for all subjects in noise, appeared to be based on first and second formant information. This was also found for the subgroup of seven subjects performing poorly pre-implantation when analysed separately. However, vowel intelligibility for this subgroup, when measured in a quiet background, was based also on vowel duration. The differences between the overall result in noise and the results of the subgroup in quiet should be attributed mainly to the noise and not to aspects of poor speech production in the subgroup. In addition, this study addresses the relationship between the intelligibility scores and objective measurements of vowel quality performed in a previous study. The results showed that the vowel intelligibility scores are mainly determined by the position of the second formant frequencies.

聋哑人工耳蜗使用者产生的元音的可理解性。
本研究探讨人工耳蜗植入对20名荷兰语后失聪受试者元音可理解性的影响。所有受试者均接受了Nucleus-22人工耳蜗植入(3台WSP和17台MSP处理器)。在植入前和植入后3个月和12个月,在打开和关闭植入物的情况下进行语音录音。元音的可理解性(单音节)是通过一组听众来确定的。在嘈杂背景下测量所有植入对象的可理解性。对于7名口语不好的受试者,测试也是在安静的背景下进行的。植入Nucleus-22装置后,结果显示,在嘈杂背景下测量的所有受试者中,大多数人(约15人)的元音清晰度都有所提高,而在安静背景下测量的说话能力差的受试者中,有大约一半的人的元音清晰度有所提高。植入后12个月,在噪声环境下测量所有受试者的元音可理解性,似乎是基于第一和第二形成峰信息。当单独分析时,这也发现了7个受试者在植入前表现不佳的亚组。然而,当在安静的背景下测量时,这一小组的元音可理解性也是基于元音的持续时间。噪声的总体结果与安静的子组结果之间的差异应主要归因于噪声,而不是子组中不良的言语产生方面。此外,本研究还探讨了先前研究中可理解度分数与元音质量客观测量之间的关系。结果表明,元音的可理解性得分主要取决于第二共振频率的位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信