Evaluation of a suture electrode for direct bladder stimulation in a lower motor neuron lesioned animal model.

J S Walter, J S Wheeler, W Cai, W W King, R D Wurster
{"title":"Evaluation of a suture electrode for direct bladder stimulation in a lower motor neuron lesioned animal model.","authors":"J S Walter,&nbsp;J S Wheeler,&nbsp;W Cai,&nbsp;W W King,&nbsp;R D Wurster","doi":"10.1109/86.769406","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study was to evaluate a \"suture\" type electrode for direct bladder stimulation in an animal model of a lower motor neuron lesion. During an initial surgery, five male cats were instrumented under anesthesia using multistranded, 316 LVM, stainless-steel, wire electrodes implanted on the bladder wall serosa above the trigone area. Electrodes were constructed with a needle attached to the end that was removed after suturing the electrode in place. Additional instrumentation included urinary bladder catheters (tubes) for pressure recording and filling, and hook type electrodes for leg and pelvic floor electromyography recording. Chronic bladder filling and stimulation studies were conducted in tethered animals three to four weeks following surgery. To test these electrodes in a spinal cord injury model, a lower motor neuron lesion was performed including the sacral cord and complete nerve roots at L6 and below. These animals were evaluated during weeks 3 and 10 after injury. Direct bladder stimulation induced active contractions and voiding both before and after spinal cord injury. Effective stimulation parameters consisted of 40 pulses per s, 300 micros to 1 ms pulse duration, a stimulation period from 3 to 4 s, and a stimulation current from 10 to 40 mA. Fluoroscopy revealed an open membranous urethra during stimulation and following stimulation. A small diameter penile urethra was observed to limit flow. Postmortem evaluation of the suture electrode revealed no abnormalities such as corrosion, migration into the bladder lumen or displacement. These findings indicate that suture electrodes are suitable and effective for short-term implantation in the lower motor neuron animal model.</p>","PeriodicalId":79442,"journal":{"name":"IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society","volume":"7 2","pages":"159-66"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/86.769406","citationCount":"36","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/86.769406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 36

Abstract

The purpose of this study was to evaluate a "suture" type electrode for direct bladder stimulation in an animal model of a lower motor neuron lesion. During an initial surgery, five male cats were instrumented under anesthesia using multistranded, 316 LVM, stainless-steel, wire electrodes implanted on the bladder wall serosa above the trigone area. Electrodes were constructed with a needle attached to the end that was removed after suturing the electrode in place. Additional instrumentation included urinary bladder catheters (tubes) for pressure recording and filling, and hook type electrodes for leg and pelvic floor electromyography recording. Chronic bladder filling and stimulation studies were conducted in tethered animals three to four weeks following surgery. To test these electrodes in a spinal cord injury model, a lower motor neuron lesion was performed including the sacral cord and complete nerve roots at L6 and below. These animals were evaluated during weeks 3 and 10 after injury. Direct bladder stimulation induced active contractions and voiding both before and after spinal cord injury. Effective stimulation parameters consisted of 40 pulses per s, 300 micros to 1 ms pulse duration, a stimulation period from 3 to 4 s, and a stimulation current from 10 to 40 mA. Fluoroscopy revealed an open membranous urethra during stimulation and following stimulation. A small diameter penile urethra was observed to limit flow. Postmortem evaluation of the suture electrode revealed no abnormalities such as corrosion, migration into the bladder lumen or displacement. These findings indicate that suture electrodes are suitable and effective for short-term implantation in the lower motor neuron animal model.

缝合电极直接膀胱刺激下运动神经元损伤动物模型的评价。
本研究的目的是评估“缝合”型电极直接膀胱刺激下运动神经元病变的动物模型。在最初的手术中,5只雄性猫在麻醉下使用多股,316 LVM,不锈钢丝电极植入膀胱壁浆膜上方的三角区。电极是用一根针连接在电极的末端,在将电极缝合到位后取出。其他仪器包括用于记录和填充压力的膀胱导管(管),以及用于记录腿部和盆底肌电图的钩式电极。慢性膀胱充盈和刺激研究在手术后三到四周的拴系动物中进行。为了在脊髓损伤模型中测试这些电极,在L6及以下进行了包括骶脊髓和完整神经根在内的下运动神经元损伤。在损伤后第3周和第10周对这些动物进行评估。脊髓损伤前后膀胱直接刺激均可诱导主动收缩和排尿。有效的刺激参数为40次脉冲/秒,脉冲持续时间为300微米至1毫秒,刺激周期为3至4秒,刺激电流为10至40 mA。在刺激期间和刺激后的透视显示一个开放的膜性尿道。小直径阴茎尿道被观察到限制流动。死后评估缝合电极显示没有异常,如腐蚀,迁移到膀胱腔或移位。这些结果表明,缝合电极短期植入下运动神经元动物模型是合适和有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信