A laboratory rig for studying aspects of worker exposure to bitumen fumes.

H C Brandt, P C de Groot
{"title":"A laboratory rig for studying aspects of worker exposure to bitumen fumes.","authors":"H C Brandt,&nbsp;P C de Groot","doi":"10.1080/00028899908984433","DOIUrl":null,"url":null,"abstract":"<p><p>This study was performed to establish which factors related to the hot application of bitumen products are relevant to worker exposure to benzene-soluble matter (as part of the total fume emission) and to the polycyclic aromatic compound (PAH) content of bitumen fume. Because personal exposure measurements in field surveys can be influenced by many uncontrollable variables, a simple laboratory rig was developed in which bitumen fumes can be generated reproducibly under well-controlled conditions. Laboratory results were related to personal exposure measurements during asphalt paving and roofing. A quantitative relationship for predicting the laboratory fume emission was derived, with bitumen volatility and temperature the only variables. The variable part of the equation is termed the fuming index (FI). The FI correlates well with measured personal exposures in asphalt paving and in roofing and can be used to predict average personal exposures during these activities if bitumen volatility, application temperature, and for paving, the asphalt type, are known. The laboratory fumes, generated at a standard temperature of 160 degrees C, are representative for fumes emitted in the temperature range relevant for asphalt paving, those generated at 250 degrees C for roofing. The PAH profiles of the fumes collected as personal samples during asphalt paving and roofing operations were similar to those of the fumes generated in the laboratory from the same bitumen and at the same temperature. Because it produces conditions representative of actual bitumen operations, this laboratory set-up is an excellent tool for assessing bitumens in terms of fuming tendency and PAH emissions/exposures.</p>","PeriodicalId":7930,"journal":{"name":"American Industrial Hygiene Association journal","volume":"60 2","pages":"182-90"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00028899908984433","citationCount":"48","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Industrial Hygiene Association journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00028899908984433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 48

Abstract

This study was performed to establish which factors related to the hot application of bitumen products are relevant to worker exposure to benzene-soluble matter (as part of the total fume emission) and to the polycyclic aromatic compound (PAH) content of bitumen fume. Because personal exposure measurements in field surveys can be influenced by many uncontrollable variables, a simple laboratory rig was developed in which bitumen fumes can be generated reproducibly under well-controlled conditions. Laboratory results were related to personal exposure measurements during asphalt paving and roofing. A quantitative relationship for predicting the laboratory fume emission was derived, with bitumen volatility and temperature the only variables. The variable part of the equation is termed the fuming index (FI). The FI correlates well with measured personal exposures in asphalt paving and in roofing and can be used to predict average personal exposures during these activities if bitumen volatility, application temperature, and for paving, the asphalt type, are known. The laboratory fumes, generated at a standard temperature of 160 degrees C, are representative for fumes emitted in the temperature range relevant for asphalt paving, those generated at 250 degrees C for roofing. The PAH profiles of the fumes collected as personal samples during asphalt paving and roofing operations were similar to those of the fumes generated in the laboratory from the same bitumen and at the same temperature. Because it produces conditions representative of actual bitumen operations, this laboratory set-up is an excellent tool for assessing bitumens in terms of fuming tendency and PAH emissions/exposures.

用于研究工人暴露于沥青烟雾的各个方面的实验室装置。
本研究旨在确定哪些与沥青产品热应用相关的因素与工人接触苯溶性物质(作为总烟雾排放的一部分)和沥青烟雾中的多环芳香族化合物(PAH)含量有关。由于现场调查中的个人暴露测量可能受到许多不可控变量的影响,因此开发了一种简单的实验室装置,该装置可以在良好控制的条件下再现沥青烟雾的产生。实验室结果与沥青铺装和屋顶期间的个人暴露测量有关。推导了以沥青挥发性和温度为唯一变量的实验室烟气排放预测的定量关系。方程的可变部分称为发烟指数(FI)。FI与沥青铺装和屋顶中测量的个人暴露有很好的相关性,如果沥青挥发性、应用温度和铺装沥青类型已知,则可用于预测这些活动中的平均个人暴露。在160摄氏度的标准温度下产生的实验室烟雾是沥青铺装相关温度范围内排放的烟雾的代表,在250摄氏度的屋顶产生的烟雾。在沥青铺路和屋顶施工过程中作为个人样本收集的烟雾的多环芳烃特征与实验室在相同温度下由相同沥青产生的烟雾相似。因为它产生了代表实际沥青操作的条件,所以该实验室设置是评估沥青发烟倾向和多环芳烃排放/暴露的极好工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信