Recommendation on mean molar activity coefficients and single ion activity coefficients of solutions for calibration of ion-selective electrodes for sodium, potassium, and calcium determination. IFCC Scientific Division Working Group on Selective Electrodes.

{"title":"Recommendation on mean molar activity coefficients and single ion activity coefficients of solutions for calibration of ion-selective electrodes for sodium, potassium, and calcium determination. IFCC Scientific Division Working Group on Selective Electrodes.","authors":"","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In principle, flame photometry measures substance concentration, and ion-selective electrodes (ISEs) measure ion activity. However, the situation regarding the comparison of results from the two techniques when applied to blood plasma is complex. The problem can be approached experimentally from the point of view of calibration of ISEs with concentration calibrators, and similar procedures are adopted for commercial ISE-based clinical analyzers. Nevertheless, there is interest in the evaluation of single ion activities in blood plasma and solutions simulating its ionic composition. Solutions are proposed for calibrating ISEs for the determination of sodium, potassium, and calcium. It is recommended that the values for single ion activities derived from the Pitzer treatment of mixed electrolyte solutions be adopted, because, although this has some empirical features, it has a sounder theoretical basis than the previously used Stokes-Robinson-Bates hydration approach.</p>","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1996-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the International Federation of Clinical Chemistry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In principle, flame photometry measures substance concentration, and ion-selective electrodes (ISEs) measure ion activity. However, the situation regarding the comparison of results from the two techniques when applied to blood plasma is complex. The problem can be approached experimentally from the point of view of calibration of ISEs with concentration calibrators, and similar procedures are adopted for commercial ISE-based clinical analyzers. Nevertheless, there is interest in the evaluation of single ion activities in blood plasma and solutions simulating its ionic composition. Solutions are proposed for calibrating ISEs for the determination of sodium, potassium, and calcium. It is recommended that the values for single ion activities derived from the Pitzer treatment of mixed electrolyte solutions be adopted, because, although this has some empirical features, it has a sounder theoretical basis than the previously used Stokes-Robinson-Bates hydration approach.

钠、钾和钙测定用离子选择电极校准用溶液的平均摩尔活度系数和单离子活度系数推荐。IFCC科学司选择性电极工作组。
原则上,火焰光度法测量物质浓度,离子选择电极(ISEs)测量离子活度。然而,当两种技术应用于血浆时,比较结果的情况是复杂的。从浓度校准器校准ise的角度来看,这个问题可以通过实验来解决,商用ise临床分析仪也采用了类似的程序。然而,人们对评估血浆中的单离子活性和模拟其离子组成的溶液感兴趣。提出了用于校准用于测定钠、钾和钙的ise的解决方案。建议采用混合电解质溶液的Pitzer处理得出的单离子活度值,因为,尽管这有一些经验特征,但它比以前使用的Stokes-Robinson-Bates水化方法有更完善的理论基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信